UPS for Printing and Printing Facilities: Press Control, Prepress Servers, and Job Loss

UPS for Printing and Printing Facilities: Press Control, Prepress Servers, and Job Loss

The cost of a power outage in printing facilities depends on what is inside the machine at the time of the outage. In the offset machine, the sheets along the paper path are wasted, the color and pressure are readjusted, and it takes minutes and dozens of sheets of paper to prepare the machine for printing again. If the job is interrupted on a digital press, it is often taken over from the beginning; for a long job, this means wasted paper and ink. Before printing, the plate imager leaves the plate unfinished when interrupted, and the job preparation servers shut down indifferently. This article discusses the three parts of the print shop — prepress, printing and finishing — and tells you which one to protect with a UPS. For factory-wide rules use of UPS in factories You can look at the article.

Three Sections, Three Different Decisions

EpisodeConnecting to UPSNon-binding
PrepressJob preparation and colour management servers, workstations, electronics of the plate exposure device, networkingHeaters of the mould bath and drying unit
PrintingMachine control unit and operator console (according to manufacturer's requirement), head and control electronics in digital machineMain drive motors, dryers, UV and IR units, compressor
FinishingControl screens of cutting and binding machines (optional)Blade and drive motors — stop safely

The prepress section is the computing part of the printing press and its rules are the same as those of a server room: the 300–1,000 W server and workstation load is protected by the online UPS, jobs are recorded in the event of an outage, and systems shut down properly. Server-side detail UPS for server room We explained it in the article.

Offset Printing Machine

The main drive motor, dryers and pumps of the offset machine are on the order of kilowatts and are not connected to the UPS. In an outage, the machine stops; the sheets in the paper path are often wasted and the UPS cannot prevent this. The benefit of the UPS is in the control layer: if the machine control unit, the operator's console and the color measurement system remain open, the job settings, color and pressure values are not lost and the machine returns to printing much faster when the power is restored. Some manufacturers define a separate UPS input for the control unit and specify the type of UPS to be connected; this information is included in the machine's installation documentation and must be read before connecting the UPS.

Digital Printing Machines

Downtime is more expensive with digital printing machines because the interrupted work can often not be resumed. The drying and heating units of large machines are on the order of kilowatts and are not connected to the UPS; the supply of the print heads, control electronics and job server can be taken to the UPS according to the manufacturer's recommendation. Moving the heads to a suitable parking position during an interruption prevents ink drying and head clogging in some machines. For large production machines, the manufacturer may request a three-phase online UPS; it comes out of the electrical table in the size and structure installation document. When to use a three-phase UPS three-phase and single-phase UPS difference We explained it in the article.

Die Exposure: Plate Loss

Devices that expose from the computer to the plate leave the plate being exposed unfinished during the interruption; the plate cannot be used and the work is re-exposed. If the control electronics of the device and the workstation to which it is connected are in the UPS, the exposure will never stop in short interruptions, and the device can complete the plate and stop safely in long interruptions. The heaters of the plate bath and drying units are not connected to the UPS.

Duration Target

In print plants, the time target is to safely stop and save the job: 10–15 minutes is enough for the prepress servers to shut down properly, the exposed plate to complete and the machine controllers to save the settings. In plants with generators, the UPS transit bridges and the control layer never closes. Time calculation How to calculate battery time We explained it in the article.

Environment: Paper Dust, Moisture and Static

The printing environment is more difficult for the UPS than it seems. Paper dust quickly clogs the fans and filters of the UPS; the clogged fan heats the device and shortens the life of the capacitors and batteries. Humidity is controlled for the behavior of the paper in the printing rooms; the UPS near the humidification systems absorbs moisture. Static electricity and ground problems affect both the press and the UPS. UPSs should be located outside the printing hall, in a clean and air-conditioned area, and if they need to remain in the hall, their filters should be cleaned regularly. Fan and condenser maintenance UPS capacitor and fan replacement, grounding UPS grounding We explained it in his articles.

Prepress Network and File Streaming

The prepress department in printing houses is not just a few servers; files from the customer, color management, job tracking software, plate exposure and job submission to the printing machines flow over the same network. If the network switch or file server shuts down during an outage, the press cannot receive work even if it is on. Therefore, the prepress UPS should carry the network switches, file and job servers, and the computer on which the job tracking software runs. Establishing communication between the UPS and the servers so that the servers automatically shut down properly in case of an interruption also prevents data loss; this Automatic shutdown We explained it in the article.

In multi-shift plants, UPS maintenance is also planned according to production: a UPS with a maintenance bypass can be checked without stopping prepress. If regular measurement of batteries and removal of paper dust are carried out at least once a year, the UPS gives the expected time at the time of an outage. Maintenance frequency UPS maintenance frequency We explained it in the article.

Common Mistakes

  • Attempting to connect the dryer or UV unit to the UPS.
  • Connecting UPS to the printing machine without looking at the manufacturer's requirement.
  • Forgetting the mold exposure device; plate loss with each interruption.
  • Leaving the UPS in the dust of paper and not cleaning the filter.
  • Forgetting the network key while protecting their prepress servers.
  • Putting UPS next to the humidification system.

The control unit of the printing machine is protected like an automation system; Rules PLC and UPS for industrial automation We explained in the article. Discovery for your facility's prepress and machine control layer: Contact Us.

The control layer is protected, not the motor and heater

In the printing press, the UPS protects the prepress servers, plate exposure electronics and control units of the presses; this saves jobs, prevents plate loss, and does not lose machine settings. Main drive motors, dryers, UV units and compressors are not connected to the UPS.
UPS coverage from prepress to post-processing in the print shop

Frequently Asked Questions

01How many kVA UPS is required for a digital printing machine?
The drying and heating unit of the machine is not connected to the UPS; the power required for the head and control electronics and the work server comes from the electrical table in the machine's installation document. For large machines, the manufacturer may request a three-phase online UPS.
02Does an offset machine work with UPS?
Due to the main drive motor and dryers, no. The UPS protects the control unit and operator console; so the settings are not lost and the machine quickly returns to the press when the power is restored.
03What to do for prepress servers?
Servers, workstations and network switch are protected by online UPS; jobs are recorded in case of interruption and systems automatically shut down properly.
04Does paper dust damage a UPS?
Yes; it clogs the fan and filters, heats the device, and shortens the capacitor and battery life. The UPS should stay outside the printing hall or its filters should be cleaned regularly.

Discovery for Your Property

Let's determine the scope of UPS from prepress to machine control in the discovery together with the conditions of the machine manufacturers; For on-site installation and maintenance in Istanbul and surrounding provinces Contact Us.

Bempower https://www.bemenerji.com/en/blog/ups-for-printing-and-printing-facilities-press-control-prepress-servers-and-job-loss