Types of Solar Panels: Monocrystalline, Polycrystalline, Half-Cut and Bifacial Panels
When you decide to buy a solar panel, one of the first questions you face is "which type?" Terms such as monocrystalline, polycrystalline, half-cut, bifacial, TOPCon, PERC and HJT appear side by side on the same product page, and they often look like alternatives to one another. In fact, they are classifications made at different levels: one describes the structure of the silicon crystal, another the way the cell is cut and connected, and another how the front and rear faces collect light.
In this guide we explain panel types by separating them into these levels. You will find how each type works, under which conditions it makes a difference, how much gain or loss it can bring in numerical examples, and what to look for on the datasheet. The article is written for home users, small business owners, technical managers and purchasing departments. We do not compare prices or brands; we focus on selection criteria.
A note: panel selection is only one link in the system. The energy a panel produces makes sense together with the inverter, the charge controller and, if needed, the battery bank. For this reason, toward the end of the article we also cover how well the panel choice matches the battery and inverter side.
How are solar panel types classified?
Listing the panels on the market in a single list is misleading. More precisely, the same panel can fall into several categories at once. For example, a panel can be monocrystalline, n-type TOPCon, half-cut and bifacial all at the same time. Thinking of the classification along three axes makes things easier.
| Axis | Question | Example types |
|---|---|---|
| Silicon crystal structure | Is the cell made from a single crystal or from multiple crystals? | Monocrystalline, polycrystalline |
| Cell architecture | How are the losses on the cell surface reduced? | PERC, TOPCon, HJT, back-contact |
| Module design | How are the cells cut and connected, and which faces collect light? | Full-cell, half-cut, shingled, bifacial, glass-glass |
| Material group | Crystalline silicon or thin film? | Crystalline silicon, thin film (CdTe, CIGS), flexible panels |
Crystalline silicon-based panels make up the vast majority of the global market; one academic assessment states that this share is above 95 percent. For this reason, the article focuses on crystalline silicon panels.

What is a monocrystalline solar panel and how efficient is it?
In a monocrystalline panel, the cells are made from wafers sliced from a single silicon crystal. The orderly arrangement of atoms means electrons meet fewer obstacles inside the cell. As a result, more electricity is generally produced from the same surface area. The cells have a dark, uniform appearance.
Sources give different ranges for typical values; one guide states that monocrystalline panel efficiency is generally between 20 and 22 percent . According to current industry data, the average efficiency of commercial TOPCon and HJT modules is reported to be around 23.5 percent in 2025 . In other words, "monocrystalline" alone is not an efficiency figure; efficiency varies with the cell architecture and the year of manufacture.
Pros and cons of monocrystalline panels
- High power density: When roof space is limited, it provides higher installed capacity from the same square meter.
- Temperature behavior: Modern monocrystalline panels generally have a lower temperature coefficient than polycrystalline ones; that is, power loss in hot weather is smaller (sources note that polycrystalline panels suffer a more pronounced efficiency loss as temperature rises, while monocrystalline panels perform better in heat ).
- Cost: Because manufacturing is more complex, it has historically been more expensive; however, as scale has grown, this gap has narrowed considerably. For current prices, check supplier quotes.
- Note: The "monocrystalline" label alone is not a guarantee of quality; the cell architecture, frame, glass and warranty terms should also be examined separately.
Does a polycrystalline panel still make sense?
In polycrystalline (multi-crystalline) panels, silicon is melted and solidified in molds; the resulting wafers consist of many small crystal grains. Because grain boundaries impede electron movement, efficiency is lower. They have a blue-toned, speckled appearance. One guide states that polycrystalline panel efficiency generally stays between 15 and 17 percent .
On the market side, the picture is clear: according to the ITRPV 2026 summary, n-type monocrystalline wafers made up about 82 percent of the wafer market in 2025 . In other words, new-generation production has shifted toward monocrystalline and n-type. You will mostly encounter polycrystalline products in old stock, on the second-hand market or in very low-budget small applications.
A polycrystalline panel can still be considered under the following conditions, but only if the product's datasheet, documentation and warranty are sound:
- If roof or land area is plentiful and there is no space constraint,
- If the system is small, the total budget is limited and the installed capacity expectation is low,
- If a panel with the same electrical characteristics needs to be added to an existing array (even in this case, voltage and current compatibility should be checked by qualified personnel).
Before buying second-hand panels or panels that have sat in storage for years, always have them tested for physical damage, micro-cracks, delamination and actual power output. The same approach applies to second-hand batteries; we covered this topic in our article on risks of a solar energy system with second-hand batteries .

PERC, TOPCon and HJT: Why does cell architecture matter?
Today, when we say "monocrystalline panel," we are actually talking about different cell architectures. Different passivation methods are used on the surface of the silicon cell to prevent the loss of electron-hole pairs (recombination). In short:
| Architecture | Short description | Notable aspect |
|---|---|---|
| PERC | Passivated rear surface, generally a p-type monocrystalline cell | Was the standard for years; its share is declining |
| TOPCon | Generally an n-type cell with an ultra-thin tunnel oxide and a doped polysilicon layer | Production similar to PERC lines; the most widespread architecture today |
| HJT | A combination of crystalline silicon and thin amorphous silicon layers | Tends toward a low temperature coefficient and high rear-side efficiency |
| Back contact (BC) | The electrical contacts are on the rear side of the cell | Little front-side shading, attractive appearance |
According to the ITRPV 2026 summary, TOPCon overtook PERC in 2024 and reached about 75 percent of crystalline silicon cell production in 2025; PERC stayed at about 14 percent and HJT at about 5 percent . This means a new panel you buy will most likely be TOPCon.
In practice, these architectural differences come down to three questions for you: How much power does it lose in hot weather (temperature coefficient)? How much light does its rear side collect (bifaciality)? What is the annual power degradation warranty? The values in the manufacturer's datasheet are the most reliable reference for answering these three questions; compare on a model-by-model basis instead of deciding by looking at a single type name.
How do half-cut panels work?
In a half-cut panel, a standard-size cell is split in two with a laser. Panels are referred to by cell counts such as 108, 120 or 144. When the cell is cut in half, the current flowing through each piece is halved.
Why does resistive loss decrease?
The power lost as heat in a conductor is proportional to the square of the current (P = I² × R). If the current is halved, the theoretical loss drops to one quarter. In practice, this gain is more limited because of additional connections; one patent description states that halving the current theoretically reduces resistive losses to one quarter, but in practice the gain stays close to half because of the additional connections . The same source writes that a 120 half-cell module typically provides 6 to 8 Wp of additional power compared with a 60-cell module.
A simple example: Suppose that in a full-cell panel the cell current is 10 A and the total series resistance is 0.02 Ω (assumption). Loss: 10² × 0.02 = 2 W. If the current drops to 5 A and the same resistance is assumed, the loss is 5² × 0.02 = 0.5 W. In a real panel the resistance distribution is different; this calculation is only meant to illustrate the principle.
How much of an advantage is there in shade?
Half-cut panels are usually arranged like two half panels, in upper and lower sections, and divided by bypass diodes. As a result, the share of power lost when a single cell is shaded is reduced. A manufacturer's blog states that with this wiring layout, a single shaded cell can disable only one sixth of the panel's power . However, this improvement does not eliminate shade: no panel technology can completely eliminate shading losses .
You can take a look at our article shading problems in solar panels and the bypass diode where we explain in detail the logic of bypass diodes and the effect of shade on a string. If the shading problem is constant or serious, correcting the layout or using a microinverter or optimizer can be more effective than choosing half-cut.
Limits of half-cut
- Because the number of cells increases, manufacturing is more complex; panel size and weight may be affected.
- Cell cutting and layer quality are important for reducing the risk of breakage or microcracks; this depends on the manufacturer's quality control.
- Half-cut alone does not mean "better technology"; it is a design choice applied together with TOPCon, PERC or HJT cells.

How much more energy do bifacial (double-sided) panels produce?
A bifacial panel converts into electricity both the sunlight arriving directly on the front side and the light reflected onto the rear side from the ground, a wall or the surroundings. They are generally glass-glass; an academic study notes that the glass-glass structure can increase long-term durability compared with conventional glass-backsheet modules . The rear-side gain is called "bifacial gain".
Factors that determine the gain
- Albedo (ground reflectivity): Light-colored gravel, white membrane or snow reflects much more light than dark asphalt or grass. NREL describes albedo as one of the biggest factors affecting bifacial performance.
- Mounting height and tilt: As the panel's height above the ground increases, the rear side receives more uniform light; however, the gain levels off beyond a certain point.
- Row spacing and self-shading: NREL's assessment notes that installation and self-shading can increase mismatch between modules and reduce the gain.
- Bifaciality factor: Shows how efficient the rear side is relative to the front side; it varies with cell architecture. It is read from the datasheet.
Bifacial gain in numbers
A review based on an NREL validation study states that in single-axis tracking systems, bifacial modules increase energy yield by 4 to 15 percent depending on module type and ground albedo . In an older NREL presentation, modeling results show a range of 4-8 percent for PERC bifacial and 6.5-11 percent for HJT bifacial . An academic global analysis reports that on typical vegetation and soil ground with an albedo of 0.25, the gain of ground-mounted bifacial modules does not exceed about 10 percent worldwide .
Example calculation (assumptions: 5 kWp ground-mounted system, annual specific yield 1,500 kWh/kWp, bifacial gain 5 percent): Monofacial production is 5 × 1,500 = 7,500 kWh. With a 5 percent gain, bifacial production is 7,500 × 1.05 = 7,875 kWh; the difference is about 375 kWh/year. On a dark roof, if the panel is mounted close to the roof and at a shallow angle, the gain can be noticeably lower; in that case, whether the extra bifacial cost will pay back must be evaluated separately.
Attention is also needed from an electrical standpoint: the extra light from the rear side increases the current. For bifacial modules, Isc values under certain reference conditions are also labeled under IEC 61730-1:2023. These values should be taken into account when selecting the charge controller or inverter input current.

When do thin-film and flexible panels come into play?
Thin-film panels (such as CdTe and CIGS) are made with very thin semiconductor layers. Their efficiency is generally lower than crystalline silicon, but in some applications lightness, flexibility or behavior in hot weather become important. Certain thin-film products are used in large-scale power plants; in home and small business applications, crystalline silicon is overwhelmingly dominant.
In applications such as caravans, boats and lightweight roofs, flexible panels (generally made by combining crystalline silicon cells with a thin, flexible lamination) are preferred. The lifespan, heat dissipation and mounting method of flexible panels differ from rigid glass panels; depending on adhesion and heating conditions, performance loss can be faster. You can find the details specific to this application in the article solar panel and battery system for caravans and boats .
Comparing panel types: Which one, in which situation?
The table below summarizes general trends. Figures vary by source and product generation; see the product datasheet for exact values.
| Type | Typical efficiency trend | Strength | Point to watch |
|---|---|---|---|
| Polycrystalline | About 15-17 percent | Small applications with a low budget and large area | Low power per area, temperature coefficient generally higher, rare in new production |
| Monocrystalline (PERC) | About 20-22 percent | Widespread and mature technology | Market share is declining; for stock products, ask about age and storage time |
| Monocrystalline (TOPCon, n-type) | Average of about 23.5 percent in commercial products | High efficiency, a trend toward better temperature behavior | Datasheet differences between models can be large |
| HJT | Close to TOPCon | Low temperature coefficient, high rear-side factor | Lower market share; the number of options may be limited |
| Half-cut (design) | Depends on cell type | Lower internal loss, sectional shading behavior | Not a technology on its own, but a design choice |
| Bifacial (design) | Front-side efficiency + rear-side gain | Meaningful gain with high albedo and high mounting | The gain is site-specific; current and mounting design matter |
For efficiency percentages, see the one that Fraunhofer ISE updates every year, Photovoltaics Report, an open source on cell and module efficiency, market and technology trends, which aims to provide up-to-date, factual information on the PV market and on cell, module and system efficiency.
Calculation examples: Area, temperature and annual loss
Example 1: Installed capacity on a limited roof area
Assumptions: usable roof area 20 m², panel size approximately 1.7 m × 1.1 m = 1.87 m², standard test condition irradiance 1,000 W/m².
- Number of panels: 20 ÷ 1.87 ≈ 10.7 → 10 panels (rounded down).
- Power of a 21% efficient monocrystalline panel: 1,000 × 1.87 × 0.21 ≈ 393 W → approximately 390 Wp.
- Power of a 16% efficient polycrystalline panel: 1,000 × 1.87 × 0.16 ≈ 299 W → approximately 300 Wp.
- Total: 10 × 390 = 3.9 kWp with monocrystalline; 10 × 300 = 3.0 kWp with polycrystalline. A difference of about 30% in the same area.
In this example, the difference is a "capacity" difference for you; it is significant if your area is limited and does not matter if you have plenty of space. To calculate how many panels you need starting from your consumption, see our guide on how many solar panels you need .
Example 2: The effect of the temperature coefficient
Panel power drops as cell temperature rises above 25 °C. Assumptions: 400 Wp panel, cell temperature of 65 °C at summer noon (40 °C above 25 °C), temperature coefficient of −0.35 %/°C for panel A and −0.29 %/°C for panel B. These values are examples; actual values are given in the datasheet.
| Panel | Loss rate | Power (for 400 Wp) |
|---|---|---|
| Panel A (−0.35 %/°C) | 40 × 0,35 = %14 | 400 × 0.86 = 344 W |
| Panel B (−0.29 %/°C) | 40 × 0,29 = %11,6 | 400 × 0.884 ≈ 354 W |
Although the difference looks like only about 10 W for a single panel, it reaches 200 W with 20 panels and repeats during summer midday hours. Our article on factors that reduce solar panel efficiency complements this calculation by covering factors such as temperature, shade, dirt and angle together.
Example 3: Annual power loss
NREL's review, which compiled roughly 2,000 published measurements, found the median degradation rate at module and system level to be 0.5% per year; the distribution is skewed toward high values and the mean is around 0.8% per year . Assumption: median loss of 0.5% and 25 years; after 25 years about (1 − 0.005)²⁵ ≈ 0.88 of the power remains, i.e. 88%. If you calculate with 0.8%, about 82% remains. This range shows why warranty statements such as "above 80% after 25 years" depend on the product and the climate. The actual expectation is determined by the annual loss value and the warranty table in the product's datasheet.
Which panel suits whom? Selection criteria
| Situation | Recommended option | Why |
|---|---|---|
| Small roof, high power target | High-efficiency monocrystalline (n-type) | Power per area is important |
| Partial shade (chimney, antenna, neighboring building) | Half-cut and, if necessary, microinverter/optimizer | The sectional structure reduces shading loss; the solution should be supported by layout |
| Ground mounting, light-colored ground | Bifacial | Rear-side gain is more meaningful |
| Hot climate, close-to-roof mounting | Products with a low temperature coefficient | Reduces summer production loss |
| Caravan, boat, lightweight structure | Small-sized rigid panel or flexible panel | Weight and mounting constraints |
| Off-grid site | Panel compatible with the battery voltage and charge controller | Voltage/current compatibility determines system efficiency |
Common mistakes
- Looking only at watts: Two panels with the same Wp can differ greatly in size, temperature coefficient and degradation warranty.
- Assuming bifacial is always "more" in every condition: On dark ground and with close-to-roof mounting, the gain is limited.
- Treating half-cut as a shading solution: It reduces shading losses but does not eliminate them.
- Mixing different panels in a string: When panels with different current and voltage values are combined in the same series string, the weakest link limits performance.
- Not checking documents: You need to verify that the document is valid for the relevant model and revision.
- Neglecting tilt and orientation: Whatever the panel type, a wrong tilt and orientation reduces efficiency. For details, see our article on solar panel angle and orientation .

How to read the panel datasheet and documents?
Every value in the datasheet is a clue to how the panel will behave in your system. The table below summarizes the most commonly used values.
| Value | What does it mean? | Why is it important? |
|---|---|---|
| Pmax (Wp) | Nominal power under standard test conditions | System sizing and price/power comparison |
| Module efficiency (%) | Power conversion relative to panel area | Capacity in limited space |
| Voc (V) | Open-circuit voltage | Rises in the cold; must not exceed the input limit of the inverter and charge controller |
| Isc (A) | Short-circuit current | Selection of charge controller and protection devices |
| Vmp / Imp | Voltage and current at maximum power point | MPPT operating range |
| Temperature coefficient (%/°C) | Rate of power loss as temperature rises | Annual production in hot climates |
| Bifaciality (%) | Efficiency of the rear side relative to the front | Bifacial gain potential |
| Performance warranty | Guaranteed power over the years | Long-term production expectation |
Two basic IEC standards stand out on the documentation side: IEC 61215 covers design qualification and durability, while IEC 61730 covers safety. According to one source's summary, IEC 61215 tests reliability and performance under stress, while IEC 61730 addresses safety risks such as electric shock, fire and mechanical hazards . It should also be remembered that these tests are a threshold, not a prediction of field lifetime: IEA PVPS Task 13 (February 2025) states that current standard tests, especially IEC 61215, cannot reveal some degradation and failure modes . Therefore, a certificate is not a quality guarantee on its own but a minimum requirement; the manufacturer's warranty and service network should also be taken into account. You can find more details on which documents and standards to look for in our article on documents to check when buying solar panels, inverters and batteries .
How does panel type affect the choice of battery, inverter and charge controller?
Panel type does not directly change the rest of the system, but it sets limits through its electrical values. These must be calculated by authorized electrical personnel during the design phase; do not attempt DC connections yourself, because panel strings are always live in daylight and high DC voltage carries a risk of arcing and fire.
- Input voltage: The total series Voc of the panels in a string must not exceed the maximum input voltage of the inverter or charge controller, even on a cold morning.
- Current: Bifacial panels and large-format high-current panels can push the device's input current limit. We explained this topic with calculation examples in the article charge controller selection: panel array, current and voltage compatibility .
- MPPT and PWM: Modern high-voltage panels are not close to the battery voltage, so they mostly require MPPT. You can find the difference in the MPPT and PWM charge controller guide.
- System type: Grid-tied, off-grid or hybrid configuration is just as important as the panel type. For a comparison, see on-grid, off-grid and hybrid systems article.
- Battery: Higher panel output does not require a larger battery; the battery is sized according to nighttime and outage needs. However, a very small battery bank paired with high panel power may operate inefficiently due to charge current limits.

If sensitive loads such as computers, servers, security cameras or network devices need to be protected during a power outage, the type of solar panel alone does not solve this need; a UPS or a suitable hybrid configuration is required in terms of transfer time and output quality. To understand this distinction, the article what an inverter is and how it differs from a UPS is a good starting point. In addition, we have also separately answered the question is a UPS still needed if solar panels are installed on the roof
Checklist when choosing panels
- Measure the available area and shading conditions; decide whether your goal is installed capacity or power per unit area.
- Find out the cell architecture (PERC, TOPCon, HJT, back-contact) and the p/n type.
- Compare the temperature coefficient and the annual power degradation warranty.
- If you are considering bifacial panels, evaluate the ground albedo, mounting height and row spacing according to the site; have the gain calculated on a project basis.
- Have the Voc, Isc and Imp values checked against the input limits of the inverter/charge controller.
- Verify that the IEC 61215 and IEC 61730 certificates are valid for the relevant model.
- Make sure that installation, connection, grounding and protection work is carried out by authorized electrical personnel.
- After installation, set up a cleaning and periodic inspection plan; for details, see solar panel cleaning and maintenance article.
Bempower support for batteries, UPS and inverters
Once you have made the right choice on the panel side, the UPS, battery bank or inverter that will supply your loads during an outage is at least as important as the panels. Bempower provides site survey, installation, periodic maintenance and technical service for every brand of UPS, battery bank and inverter. If you would like to plan the right solution for your existing system together, you can contact us via our contact page
- Photovoltaic Degradation Rates - An Analytical Review — NREL (Jordan and Kurtz), 2012. https://docs.nlr.gov/docs/fy12osti/51664.pdf
- Photovoltaics Report — Fraunhofer ISE, 2026. https://www.ise.fraunhofer.de/en/publications/studies/photovoltaics-report.html
- Optimization and Performance of Bifacial Solar Modules: A Global Perspective — arXiv (Khan et al.), 2017. https://arxiv.org/pdf/1709.10026
- Half-cell solar modules: the new standard in PV production — Photovoltaics International (PV Tech), 2018. https://www.pv-tech.org/wp-content/uploads/legacy-publication-pdfs/ee2a36add1-halfcell-solar-modules-the-new-standard-in-pv-production.pdf
- Solar Panel Certifications Explained: IEC 61215, IEC 61730 and MCS — Commercial Solar PV, 2026. https://commercialsolarpv.uk/blog/solar-panel-certifications-iec/
- Future of Solar Module: TOPCon, HJT and Perovskite (ITRPV 2026 summary) — The Battery Magazine, 2026. https://www.thebatterymagazine.com/future-of-solar-module-topcon-hjt-and-perovskite/
Sources