Bempower Myon MYLONG-1000 1 kVA Online UPS (with Additional Charging Card)
Bempower Myon MYLONG-1000 1 kVA Online UPS (with Additional Charging Card)
- Model code
- MYLONG-1000
- Series
- Myon
- Status
- Zero
- Stock
- Sold out
- Category
- Single-Phase Online UPS (1/1)
- Warranty
- 2 year
1 kVA / 900 W single-phase online double-conversion UPS; compatible with an external battery bank (for extended runtime) when equipped with an optional charging card; external battery bank (12 V, 7–9 Ah, with optional charging card); LCD display. Myon series, 2-year warranty.
-
CE
General Features
- High frequency true double-conversion
- DSP technology
- Input power factor correction (PFC)
- Wide input voltage range (110~300 V)
- Cold start
- Automatic frequency detection
- ECO mode
- Selectable output voltage from LCD display
- 50/60 Hz frequency conversion mode
- Boot self-testing
- Advanced battery management (ABM)
- Short circuit and overload protection
- Automatic battery charging in the switched off position
- Intelligent load-sensing fan control
- Excellent generator compatibility
- Standard RS232 communication port
- USB/SNMP communication port (optional)
- Emergency shutdown (EPO) (optional)
- Add-on battery unit with additional magazine card
- EMC – LVD CE certificates
- 2 years warranty / 10 years spare parts warranty
Rear Panel
- AC input
- Battery connector
- Fan
- USB (optional)
- EPO (optional)
- RS232
- SNMP/AS400 (optional)
- Exodus
Where is it used?
Myon MYLONG-1000 1 kVA online (double conversion) UPS with external battery pack long-term Designed to work: The additional charging card can fill large battery banks, the battery turnover time is 0ms when the power is cut off, and the output is full sine. Suitable for systems that need to operate during long outages:
- Homes and businesses in areas where the outage can last for hours
- Combi boilers and heating systems
- Camera, alarm and security systems
- Server and network cabinets
- Telecom and remote field equipment
- Automation and control cabinets
Loads that should not be connected: devices such as laser printers, heaters, irons, water heaters, air conditioners with high inrush current or continuous high power overload the UPS and consume battery time in a short time; connect these devices to a normal outlet, not to the UPS.
Which devices run and how much? (calculated, estimated)
This model with external battery pack works; the time varies according to the capacity of the selected battery group. The following times are manufacturer measurement It is not; with sample battery packs Calculated Estimate (new, fully charged batteries, 25 °C).
| Battery group | 25% load (225 W) | 50% load (450 W) | 100% load (900 W) |
|---|---|---|---|
| 3 × 12 V 40 Ah | ~4.1 hours | ~1.7 hours | ~38 min |
| 3 × 12 V 70 Ah | ~8.6 hours | ~3.5 hours | ~1.4 hours |
| 3 × 12 V 100 Ah | ~13.6 hours | ~6.4 hours | ~2.6 hours |
How was it calculated? This model works with a 36 V (3 × 12 V) battery group; the 40 / 70 / 100 Ah groups in the table are examples. The times were read from the constant power tables (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheets for AGM batteries of the same capacity. When operating from the battery, the inverter efficiency was taken from 85% in the manufacturer's data. Method detail: How to calculate battery time?
The battery group is designed according to your needs (desired time, load, charging time, location); in larger groups, the charging time is also extended. Let's calculate the right group for you together: Contact Us.
The actual time varies according to the age of the batteries, temperature and variability of the load; the time is significantly shortened in aged batteries. Since the UPS's own consumption is dominant in very small loads, the time cannot be calculated with this method.
How much load does it carry?
The strength of this model 1,000 VA / 900 W(output power factor 0.9). The sum of the connected devices should not exceed both the VA and watt limits.
Continuous load up to 720 W (80% of the power). This allowance covers the short-term high current of the devices at power-up, extends the operating time from the battery and leaves room for growth.
- Overload resistance: 1 min at 105–125% load; 30 sec at 125–150% load; 300 ms above 150% (then bypass)
- 0ms switching from mains to battery, full sine output
- Input power factor ≥ 0.98 — works with the generator
- Short circuit, overload and battery deep discharge protection
If you don't know the total power of the devices you're connecting Power Calculation tool.
What can be done to extend the working time?
- Connect only the necessary devices. Plug devices that do not need to operate in an outage into a normal outlet, not into a UPS.
- Reduce the load. When the load is halved, the time is more than doubled (see table above).
- Shut down systems with confidence. The communication port of the UPS (RS232/USB/SNMP) can be used with the appropriate monitoring software for the servers and computers to shut down properly during a long outage.
- Select the battery pack as per requirement. The time is extended by the capacity of the battery group (table above). The larger the group, the longer the charging time; the charging current of this model is 6 A (12 A optional).
- Keep the battery room cool. The capacity and lifespan of batteries are affected by temperature; keep batteries in a ventilated location out of direct sunlight.
- Allow time for charging after downtime. In large battery banks, a full charge takes hours; in case of consecutive outages, the duration of the second outage is shorter.
Service life and battery replacement
Batteries: This model is powered by an external battery bank; the life of the batteries depends on the class of battery selected. Large-capacity AGM batteries have a design life of up to 10 years at 20 °C in manufacturer data sheets; the actual life is shorter according to the ambient temperature and frequency of outages. The battery room should be kept cool and ventilated, and the batteries should be measured at least once a year.
Have the batteries checked or replaced if:
- If the duration of the interruption has been significantly shortened compared to the previous
- If the UPS gives a battery warning or shows an error in the battery test
- If there is swelling, leakage or odor in the battery case
- If the batteries are over 3 years old (annual measurement is recommended)
Detailed information: When should a UPS battery be replaced?
Batteries in a battery string togetheris replaced with a new one of the same capacity and type; the old and new battery are not mixed in the same sequence. Why?
Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. In online UPSs, fans and capacitors are parts that wear out over time; they are checked during periodic maintenance. The device is guaranteed for 2 years, and the spare part is provided for 10 years.
Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.
General Features
- High frequency true double-conversion
- DSP technology
- Input power factor correction (PFC)
- Wide input voltage range (110~300 V)
- Cold start
- Automatic frequency detection
- ECO mode
- Selectable output voltage from LCD display
- 50/60 Hz frequency conversion mode
- Boot self-testing
- Advanced battery management (ABM)
- Short circuit and overload protection
- Automatic battery charging in the switched off position
- Intelligent load-sensing fan control
- Excellent generator compatibility
- Standard RS232 communication port
- USB/SNMP communication port (optional)
- Emergency shutdown (EPO) (optional)
- Add-on battery unit with additional magazine card
- EMC – LVD CE certificates
- 2 years warranty / 10 years spare parts warranty
Rear Panel
- AC input
- Battery connector
- Fan
- USB (optional)
- EPO (optional)
- RS232
- SNMP/AS400 (optional)
- Exodus
| Series | Myon |
|---|---|
| Power | 1 kVA |
| Active power | 900 W |
| Phase structure | Single-phase (1/1) |
| Topology | Online double-loop |
| Cabin type | Tower |
| Output power factor | 0,9 |
| Waveform | Pure sine wave |
| Battery voltage | 36 Vdc |
| Number of batteries | 3 number |
| Battery type | External battery pack (12 V 7–9 Ah, with additional charging card) |
| Long-term (additional recharge card) | Yes |
| Charging current | 6 A (12 A optional) |
| Transfer period | Mains to battery 0 ms |
| Parallel processing | None |
| Screen | LCD |
| Communications | RS232 standard; USB/SNMP/AS400, EPO optional |
| Dimensions (WxDxH) | 144 × 336 × 216 mm |
| Net weight | 6 kg |
| Warranty | 2 years / 10 years spare parts |
| Input voltage | 208 / 220 / 230 / 240 Vac |
| Input voltage range | 110–176 VAC (linear reduction at 50%–100% load); 176–280 VAC (no reduction); 280–300 VAC (50% reduction) |
| Input frequency | 40–70 Hz (automatic detection) |
| Input power factor | ≥ 0.98 |
| Bypass voltage range | -25% to +15%, selectable via the LCD panel |
| Output voltage | 208 / 220 / 230 / 240 Vac, selectable via the LCD panel |
| Voltage regulation | ±1% |
| Output frequency | 45–55 Hz or 55–65 Hz (synchronized); 50/60 Hz ±0.1 Hz (battery mode) |
| Crest factor | 3:1 |
| Battery charging time | 90% capacity in 8 hours |
| Alarms | Mains failure every 4 seconds; low battery every 1 second; overload twice per second; general error continuously |
| Operating temperature / humidity / protection | 0–40 °C, 20–90% (non-condensing), IP20 |
| Monitoring software | RS232 standard, USB optional (Windows software); power management via SNMP manager and web browser using SNMP (optional) |
| Noise (1 m) | ≤ 50 dB |
| Standards | Safety IEC/EN 62040-1, 62477-1; EMC IEC/EN 62040-2, IEC 61000-4-2/3/4/5/6/8 |
| Harmonic distortion | ≤ 2% for linear loads; ≤ 5% for non-linear loads |
| Efficiency (from the grid) | ≥ 90% |
| Efficiency from the battery | ≥ 85% |
| ECO efficiency | ≥ 95% |
| Overload | 105–125%: 1 min; 125–150%: 30 sec; >150%: 300 ms (bypass) |
| Packaged dimensions (WxDxH) | 232 × 417 × 318 mm |
| Gross weight | 7 kg |
| Warranty | 2 year |
| Weight | 6 kg |
| Status | Zero |
| Stock | Sold out |
The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.
Delivery Process
- It will be shipped within 1–3 business days.
- The tracking number is shared by email and in My Account → My Orders.
- When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
- Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.
Returns and exchanges
- You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
- The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
- Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
- Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
- Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
- The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.
Customer reviews
There are no reviews for this product yet.
If you've used this product, share your experience—be the first to leave a review.
Rate this product
- Your rating and a few sentences will help guide other customers.
- You decide whether your name, city, and photo will be displayed.
- If you purchased it from us, the "Purchased" badge will appear in your review.
Log in to post a comment.