Bempower Myon 3 kVA Rack/Tower Online UPS
Bempower Myon 3 kVA Rack/Tower Online UPS
- Model code
- RT-3000
- Series
- Myon
- Status
- Zero
- Stock
- Sold out
- Category
- Single-Phase Online UPS (1/1)
- Warranty
- 2 year
3 kVA / 2700 W single-phase online double-conversion UPS; can be used as a rack-mounted or tower unit, 6 × 12 V 7–9 Ah internal batteries (L: 96 Vdc, 8 external batteries), LCD display. Myon series, 2-year warranty.
-
CE
General Features
- High frequency true double-conversion
- DSP technology
- Input power factor correction (PFC)
- Wide input voltage range (110~300 V)
- Output power factor 0.9
- Cold start
- Automatic frequency detection
- ECO mode
- 50/60 Hz frequency conversion mode
- Selectable output voltage and bypass from LCD display
- Power-on self-test, advanced battery management (ABM)
- Short circuit and overload protection
- Automatic battery charging in the switched off position
- Intelligent load-sensing fan control
- Generator compatibility
- Standard RS232; USB/SNMP optional
- EPO (optional)
- Add-on battery unit with additional magazine card (optional)
- EMC – LVD CE
- 2 years warranty / 10 years spare parts warranty
Rear Panel
- AC input
- Battery connector (optional)
- Fan
- USB (optional)
- EPO (optional)
- RS232
- SNMP/AS400 (optional)
- Exodus
Where is it used?
Myon 3 kVA Rack/Tower online (double conversion) The UPS feeds the load from its own inverter at any time; when the power is cut off, the transition time to the battery is 0 ms and the output is full sine. Suitable for devices sensitive to interruption and voltage disturbance:
- Use in 19-inch racks or towers
- Servers, networking and communication cabinets
- Camera recording systems and security boards
- Devices that require full sine voltage such as combi boilers
- Laboratory and measuring devices
- Automation and control panels (PLC)
- Office computers and POS systems
Loads that should not be connected: devices such as laser printers, heaters, irons, water heaters, air conditioners with high inrush current or continuous high power overload the UPS and consume battery time in a short time; connect these devices to a normal outlet, not to the UPS.
Which devices run and how much? (calculated, estimated)
The following times are manufacturer measurement It is not; According to the battery arrangement of the device Calculated Estimate values. Valid for new and fully charged batteries in a 25 °C environment.
| Connected load | Total load | Estimated time |
|---|---|---|
| Server + network switch + modem | 455 W | ~31 min |
| 3 workstations (computer + monitor) + network switch | 580 W | ~23 min |
| 2 servers + network switch + NAS | 900 W | ~13 min |
| Half load (50%) | 1.4 kW | ~7 min |
| 4 servers + 2 network switches + NAS | 1.7 kW | Less than 5 min |
| Full load (100%) | 2.7 kW | Less than 5 min |
How was it calculated? This model has a 6 × 12 V 7–9 Ah battery; the times are read from the constant power table (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheet for an AGM battery of class 7 Ah — with 9 Ah batteries, the duration is slightly longer. When operating from the battery, the inverter efficiency is taken from 87% in the manufacturer's data. The device wattage values are on our website Power Calculation tool; the value on the label of your own devices may be different. Detail of the method: How to calculate battery time?
The actual time varies according to the age of the batteries, temperature and variability of the load; the time is significantly shortened in aged batteries. Since the UPS's own consumption is dominant in very small loads, the time cannot be calculated with this method.
How much load does it carry?
The strength of this model 3,000 VA / 2,700 W(output power factor 0.9). The sum of the connected devices should not exceed both the VA and watt limits.
Continuous load up to 2.2 kW (80% of the power). This allowance covers the short-term high current of the devices at power-up, extends the operating time from the battery and leaves room for growth.
- Overload resistance: 1 min at 105–125% load; 30 sec at 125–150% load; 300 ms above 150% (then bypass)
- 0ms switching from mains to battery, full sine output
- Input power factor ≥ 0.99 — works with generator
- Short circuit, overload and battery deep discharge protection
If you don't know the total power of the devices you're connecting Power Calculation tool.
What can be done to extend the working time?
- Connect only the necessary devices. Plug devices that do not need to operate in an outage into a normal outlet, not into a UPS.
- Reduce the load. When the load is halved, the time is more than doubled (see table above).
- Shut down systems with confidence. The communication port of the UPS (RS232/USB/SNMP) can be used with the appropriate monitoring software for the servers and computers to shut down properly during a long outage.
- Keep the batteries cool. Do not place the UPS and batteries in direct sunlight, close to a heat source, or in stuffy places; the operating temperature is 0–40 °C.
- Allow time for charging after downtime. Batteries are filled to 90% capacity in 8 hours. In case of consecutive outages, the duration of the second outage is shorter.
- If longer is required An external battery unit can be added to this model with an additional magazine card (optional). Powered by an external battery pack where hours are needed long-term online UPS models.
Service life and battery replacement
Batteries: this model uses a 6 × 12 V 7–9 Ah maintenance-free dry type (VRLA-AGM) battery. The design life of this class of batteries at 20 °C is usually 5 years in the manufacturer's data sheets. Changes in the UPS depending on the temperature and frequency of interruptions are often 3–5 years required. As the ambient temperature rises, the battery life is significantly shortened.
Have the batteries checked or replaced if:
- If the duration of the interruption has been significantly shortened compared to the previous
- If the UPS gives a battery warning or shows an error in the battery test
- If there is swelling, leakage or odor in the battery case
- If the batteries are over 3 years old (annual measurement is recommended)
Detailed information: When should a UPS battery be replaced?
Batteries in a battery string togetheris replaced with a new one of the same capacity and type; the old and new battery are not mixed in the same sequence. Why?
Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. In online UPSs, fans and capacitors are parts that wear out over time; they are checked during periodic maintenance. The device is guaranteed for 2 years, and the spare part is provided for 10 years.
Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.
General Features
- High frequency true double-conversion
- DSP technology
- Input power factor correction (PFC)
- Wide input voltage range (110~300 V)
- Output power factor 0.9
- Cold start
- Automatic frequency detection
- ECO mode
- 50/60 Hz frequency conversion mode
- Selectable output voltage and bypass from LCD display
- Power-on self-test, advanced battery management (ABM)
- Short circuit and overload protection
- Automatic battery charging in the switched off position
- Intelligent load-sensing fan control
- Generator compatibility
- Standard RS232; USB/SNMP optional
- EPO (optional)
- Add-on battery unit with additional magazine card (optional)
- EMC – LVD CE
- 2 years warranty / 10 years spare parts warranty
Rear Panel
- AC input
- Battery connector (optional)
- Fan
- USB (optional)
- EPO (optional)
- RS232
- SNMP/AS400 (optional)
- Exodus
- UPS
- uninterruptible power supply
- online UPS
- 3 kVA UPS
- single-phase UPS
- Myon Series
- Bempower
- rack-mounted UPS
| Series | Myon |
|---|---|
| Power | 3 kVA |
| Active power | 2700 W |
| Phase structure | Single-phase (1/1) |
| Topology | Online double-loop |
| Cabin type | Rack / Tower |
| Output power factor | 0,9 |
| Waveform | Pure sine wave |
| Battery voltage | 72 Vdc |
| Number of batteries | 6 number |
| Battery type | 6 × 12 V 7–9 Ah internal (L: 96 Vdc, 8 battery external) |
| Long-term (additional recharge card) | Nope |
| Charging current | 1 A (standard); 6 A (long-term L model) |
| Transfer period | 0 ms from the mains to the battery; 4 ms from the inverter to the bypass |
| Parallel processing | None |
| Screen | LCD |
| Communications | RS232 standard; USB/SNMP/AS400, EPO optional |
| Dimensions (WxDxH) | 440 × 560 × 88 (S) / 440 × 468 × 88 (L) mm |
| Net weight | 26,8 kg |
| Warranty | 2 years / 10 years spare parts |
| Input voltage | 208 / 220 / 230 / 240 Vac |
| Input voltage range | 110–176 VAC (linear reduction at 50%–100% load); 176–280 VAC (no reduction); 280–300 VAC (50% reduction) |
| Input frequency | 40–70 Hz (automatic detection) |
| Input power factor | ≥ 0.99 |
| Bypass voltage range | –25% to +15% (selectable) |
| Input THD | ≤ 6% |
| Output voltage | 208 / 220 / 230 / 240 Vac, selectable via LCD panel |
| Voltage regulation | ±1% |
| Output frequency | 45–55 / 55–65 Hz synchronous; 50/60 Hz ±0.1 Hz in battery mode |
| Crest factor | 3:1 |
| Harmonic distortion (THDv) | ≤ 2% for linear loads; ≤ 5% for non-linear loads |
| Overload | 105–125%: 1 min; 125–150%: 30 sec; >150%: 300 ms (bypass) |
| Battery charge time | 90% capacity in 8 hours |
| Alarms | Audible warning every 4 seconds during grid failure, every 1 second during low battery, twice per second during overload; continuous audible warning during general failure |
| Protections | Short circuit, overload, overheating, battery deep discharge, fan test |
| Operating temperature / humidity / protection | 0–40 °C, 20–90% (non-condensing), IP20 |
| Monitoring software | RS232 standard, USB optional (Windows software); power management via SNMP (optional) using an SNMP manager and web browser |
| Noise (1 m) | ≤ 50 dB |
| Standards | Safety IEC/EN 62040-1, 62477-1; EMC IEC/EN 62040-2, IEC 61000-4-2/3/4/5/6/8 |
| Efficiency (from the grid) | ≥ 92% |
| Efficiency from battery | ≥ 87% |
| ECO efficiency | ≥ 97% |
| Packaged dimensions (WxDxH) | 590 × 690 × 201 (S) / 590 × 592 × 201 (L) |
| Gross weight | 29.7 kg (S) / 13.6 kg (L) |
| Net weight (L) | 10.1 kg |
| Warranty | 2 year |
| Weight | 26,8 kg |
| Status | Zero |
| Stock | Sold out |
The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.
Delivery Process
- It will be shipped within 1–3 business days.
- The tracking number is shared by email and in My Account → My Orders.
- When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
- Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.
Returns and exchanges
- You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
- The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
- Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
- Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
- Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
- The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.
Customer reviews
There are no reviews for this product yet.
If you've used this product, share your experience—be the first to leave a review.
Rate this product
- Your rating and a few sentences will help guide other customers.
- You decide whether your name, city, and photo will be displayed.
- If you purchased it from us, the "Purchased" badge will appear in your review.
Log in to post a comment.
This product has been reviewed 56 times