Bempower Myon 1500 VA Line Interactive UPS
Bempower Myon 1500 VA Line Interactive UPS
- Model code
- 1500
- Series
- Myon
- Status
- Zero
- Stock
- Sold out
- Category
- Line Interactive UPS
- Warranty
- 2 year
1.5 kVA / 900 W single-phase line interactive UPS; 2 × 12 V 9 Ah battery, LED display. Myon series, 2 years warranty.
-
CE
General Features
- LED control panel
- Microprocessor digital control
- Automatic voltage adjustment (AVR)
- Wide input voltage range (170~280 V)
- Automatic fuse
- Easy-to-understand alarm system
- Output power factor 0.6
- Cold start
- Simulated sine wave output
- Intelligent battery control system
- Short circuit and overcurrent protection
- Battery deep discharge protection
- Automatic frequency detection
- Shutdown in no-load operation in battery mode
- Boot self-testing
- Automatic battery charging in the switched off position
- RS232 / USB communication port (optional)
- LCD display (optional)
- EMC – LVD CE
- 2 years warranty / 10 years spare parts warranty
Rear Panel
- Exodus
- Wire/modem/fax protection (optional)
- USB (optional)
- Introduction
- Insurance
- Fan (2000 VA)
Where is it used?
The Myon 1,500 VA line interactive UPS supplies the connected devices from the battery when the power is cut off or the voltage drops; it also corrects the fluctuation in the mains voltage with automatic voltage adjustment (AVR). Suitable for small and medium-power electronic devices:
- Home and small office computers
- Modem, router and network switch
- Camera recorder (NVR / DVR) and IP cameras
- POS device and cash register
- Alarm and card access panels
- Satellite receiver and television
Not recommended loads: Since the output wave is simulated sine, it has a full sine output for motorized devices such as combi boilers, circulation pumps, refrigerators and medical devices. UPS online recommended. High-power devices such as laser printers, heaters, irons, kettles should not be connected to any UPS model.
Which devices run and how much? (calculated, estimated)
The following times are manufacturer measurement It is not; According to the battery arrangement of the device Calculated Estimate values. Valid in a 25 °C environment with a new and fully charged battery.
| Connected devices | Total load | Estimated time |
|---|---|---|
| POS / cash register + laptop + modem | 140 W | ~35 min |
| Desktop computer + 24" monitor + modem | 195 W | ~23 min |
| 2 desktop computers + 2 monitors + modem | 375 W | ~7 min |
| Server + network switch + modem | 455 W | ~5 min |
| 3 desktop computers + 3 monitors + modem + network switch | 595 W | Less than 5 min |
| Full load (100%) | 900 W | Less than 5 min |
How was it calculated? This model has a 2 × 12 V 9 Ah battery. The times are read from the constant power table (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheet of an AGM battery of the same class. The inverter efficiency is considered to be 85% when operating from the battery (the manufacturer has not published an efficiency value for this model). The device wattage values are on our website Power Calculation tool; the value on the label of your own devices may be different. Detail of the method: How to calculate battery time?
The actual time varies according to the age of the battery, temperature and variability of the load. In aged batteries, the time is significantly shortened. For very small loads (such as only a modem), the time cannot be calculated with this method, as the UPS's own consumption is dominant; in addition, if the device is unloaded while running from the battery, it shuts itself down.
How much load does it carry?
The strength of this model 1,500 VA / 900 W. Since the output power factor is 0.6, the total of connected devices should not exceed both 1,500 VA and 900 W. For devices such as computers and monitors, the wattage limit is usually decisive.
Continuous load up to 720 W (80% of the power). This allowance covers the short-term high current of the devices at power-up, extends the runtime from the battery, and makes the UPS run cooler.
- 3 outlet sockets
- Audible warning when overload and battery is low
- Fuse and electronic protection in the mains, electronic short circuit protection when working from the battery
- Battery deep discharge protection
If you don't know the total power of the devices you're connecting Power Calculation tool.
What can be done to extend the working time?
- Connect only the necessary devices. Plug devices that are not needed during an interruption, such as printers, speakers, additional monitors, into a normal outlet, not into the UPS.
- Reduce the load. When the load is halved, the time is more than doubled (see table above).
- Shut down the computer safely. If the interruption is prolonged, save the open files and turn off the computer. With the optional USB/RS232 communication port and the appropriate monitoring software, this shutdown can be automated.
- Keep the batteries cool. Do not place the UPS in direct sunlight, near the heater or in closed cabinets; the operating temperature is 0–40 °C.
- Allow time for charging after downtime. Batteries are charged to 90% capacity in 6–8 hours. In case of consecutive outages, the duration of the second outage is shorter.
- If longer is required This series is not designed to connect an external battery. With an additional charging card for a long time, external battery can be connected single-phase online UPS models.
Service life and battery replacement
Batteries: this model uses a 2 × 12 V 9 Ah maintenance-free dry type (VRLA-AGM) battery. The design life of this class of batteries at 20 °C is usually 5 years in the manufacturer's data sheets. Changes in the UPS depending on the temperature and frequency of interruptions are often 3–5 years required. As the ambient temperature rises, the battery life is significantly shortened.
Have the batteries checked or replaced if:
- If the duration of the interruption has been significantly shortened compared to the previous
- If the UPS gives a battery warning or shows an error in the power-on test
- If there is swelling, leakage or odor in the battery case
- If the batteries are over 3 years old (annual measurement is recommended)
Detailed information: When should a UPS battery be replaced?
Two batteries in models with two batteries togethermust be replaced with a new one of the same capacity and type; the old and new battery are not mixed.
Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. The device is guaranteed for 2 years, and the spare part is provided for 10 years.
Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.
General Features
- LED control panel
- Microprocessor digital control
- Automatic voltage adjustment (AVR)
- Wide input voltage range (170~280 V)
- Automatic fuse
- Easy-to-understand alarm system
- Output power factor 0.6
- Cold start
- Simulated sine wave output
- Intelligent battery control system
- Short circuit and overcurrent protection
- Battery deep discharge protection
- Automatic frequency detection
- Shutdown in no-load operation in battery mode
- Boot self-testing
- Automatic battery charging in the switched off position
- RS232 / USB communication port (optional)
- LCD display (optional)
- EMC – LVD CE
- 2 years warranty / 10 years spare parts warranty
Rear Panel
- Exodus
- Wire/modem/fax protection (optional)
- USB (optional)
- Introduction
- Insurance
- Fan (2000 VA)
- UPS
- Uninterruptible Power Supply
- Line Interactive UPS
- 1
- 5 kVA UPS
- Single Phase UPS
- Myon Series
- BEMPOWER
| Series | Myon |
|---|---|
| Power | 1,5 kVA |
| Active power | 900 W |
| Phase structure | Single-phase (1/1) |
| Topology | Line Interactive |
| Cabin type | Tower |
| Output power factor | 0,6 |
| Waveform | Simulated sine wave |
| Battery voltage | 24 Vdc |
| Number of batteries | 2 number |
| Battery type | 2 × 12 V 9 Ah |
| Long-term (additional recharge card) | Nope |
| Transfer period | < 8–10 ms |
| Parallel processing | None |
| Screen | LED |
| Communications | RS232 / USB (optional) |
| Dimensions (WxDxH) | 136 × 328 × 186 mm |
| Net weight | 9,4 kg |
| Warranty | 2 years / 10 years of spare parts |
| Input voltage | 220 / 230 / 240 VAC; range 162–295 VAC |
| Input frequency | 50/60 Hz automatic detection |
| Output voltage regulation | ±10% (battery operation) |
| Output frequency | 50/60 Hz ± 1 Hz |
| Battery protection | Overload, short circuit, deep discharge, overcharge protection |
| Battery management | Yes |
| Display indicators | Green LED for normal mains operation / yellow LED for battery operation / red LED for fault |
| Alarms | Audible alerts for battery operation, low battery, and overload |
| Battery start (cold start) | Yes |
| Short-circuit protection | AC fuse + electronic protection on the mains; electronic protection on the battery |
| Voltage regulation | 2-step boost and AVR |
| Operating temperature | 0–40 °C |
| Noise (1 m) | < 45 dB |
| Standards | Safety IEC/EN 62040-1; EMC IEC/EN 62040-2 |
| Outlets | 3 |
| Packaged dimensions (WxDxH) | 185 × 374 × 269 mm |
| Gross weight | 10 kg |
| Battery charging time | 6–8 hours to 90% capacity |
| Warranty | 2 year |
| Weight | 9,4 kg |
| Status | Zero |
| Stock | Sold out |
The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.
Delivery Process
- It will be shipped within 1–3 business days.
- The tracking number is shared by email and in My Account → My Orders.
- When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
- Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.
Returns and exchanges
- You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
- The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
- Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
- Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
- Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
- The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.
Customer reviews
There are no reviews for this product yet.
If you've used this product, share your experience—be the first to leave a review.
Rate this product
- Your rating and a few sentences will help guide other customers.
- You decide whether your name, city, and photo will be displayed.
- If you purchased it from us, the "Purchased" badge will appear in your review.
Log in to post a comment.
This product has been reviewed 50 times