TCMB foreign exchange selling rate · 24.11.2026: USD 50,63 ₺ EUR 55,32 ₺

Bempower Myon 1000 VA Line Interactive UPS

Sold out
Bempower

Bempower Myon 1000 VA Line Interactive UPS

Model code
1000
Series
Myon
Status
Zero
Stock
Sold out
Warranty
2 year
There are no reviews yet — be the first to write a review
Sold out supplying, you can request a quote

1 kVA / 600 W single-phase line-interactive UPS; 2 × 12 V 7 Ah batteries, LED display. Myon series, 2-year warranty.

  • CE Conformity Mark CE
  • Description
  • Technical Specifications
  • Documents (1)
  • Delivery and Returns
  • Comments (0)

General Features

  • LED control panel
  • Microprocessor digital control
  • Automatic voltage adjustment (AVR)
  • Wide input voltage range (170~280 V)
  • Automatic fuse
  • Easy-to-understand alarm system
  • Output power factor 0.6
  • Cold start
  • Simulated sine wave output
  • Intelligent battery control system
  • Short circuit and overcurrent protection
  • Battery deep discharge protection
  • Automatic frequency detection
  • Shutdown in no-load operation in battery mode
  • Boot self-testing
  • Automatic battery charging in the switched off position
  • RS232 / USB communication port (optional)
  • LCD display (optional)
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Rear Panel

  1. Exodus
  2. Wire/modem/fax protection (optional)
  3. USB (optional)
  4. Introduction
  5. Insurance
  6. Fan (2000 VA)

Where is it used?

The Myon 1,000 VA line interactive UPS supplies the connected devices from the battery when the power is cut off or the voltage drops; it also corrects the fluctuation in the mains voltage with automatic voltage adjustment (AVR). Suitable for small and medium-power electronic devices:

  • Home and small office computers
  • Modem, router and network switch
  • Camera recorder (NVR / DVR) and IP cameras
  • POS device and cash register
  • Alarm and card access panels
  • Satellite receiver and television

Not recommended loads: Since the output wave is simulated sine, it has a full sine output for motorized devices such as combi boilers, circulation pumps, refrigerators and medical devices. UPS online recommended. High-power devices such as laser printers, heaters, irons, kettles should not be connected to any UPS model.

Which devices run and how much? (calculated, estimated)

The following times are manufacturer measurement It is not; According to the battery arrangement of the device Calculated Estimate values. Valid in a 25 °C environment with a new and fully charged battery.

Connected devicesTotal loadEstimated time
POS / cash register + laptop + modem140 W~34 min
Desktop computer + 24" monitor + modem195 W~22 min
Half load (50%)300 W~12 min
2 desktop computers + 2 monitors + modem375 W~9 min
Server + network switch + modem455 W~6 min
Full load (100%)600 WLess than 5 min

How was it calculated? This model has a 2 × 12 V 7 Ah battery. The times are read from the constant power table (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheet for an AGM battery of the same class. The inverter efficiency when operating from the battery is considered to be 85% (the manufacturer has not published an efficiency value for this model). The device wattage values are available on our website Power Calculation tool; the value on the label of your own devices may be different. Detail of the method: How to calculate battery time?

The actual time varies according to the age of the battery, temperature and variability of the load. In aged batteries, the time is significantly shortened. For very small loads (such as only a modem), the time cannot be calculated with this method, as the UPS's own consumption is dominant; in addition, if the device is unloaded while running from the battery, it shuts itself down.

How much load does it carry?

The strength of this model 1,000 VA / 600 W. Since the output power factor is 0.6, the total of the connected devices should not exceed both 1,000 VA and 600 W. For devices such as computers and monitors, the wattage limit is usually decisive.

Continuous load up to 480 W (80% of the power). This allowance covers the short-term high current of the devices at power-up, extends the runtime from the battery, and makes the UPS run cooler.

  • 3 outlet sockets
  • Audible warning when overload and battery is low
  • Fuse and electronic protection in the mains, electronic short circuit protection when working from the battery
  • Battery deep discharge protection

If you don't know the total power of the devices you're connecting Power Calculation tool.

What can be done to extend the working time?

  • Connect only the necessary devices. Plug devices that are not needed during an interruption, such as printers, speakers, additional monitors, into a normal outlet, not into the UPS.
  • Reduce the load. When the load is halved, the time is more than doubled (see table above).
  • Shut down the computer safely. If the interruption is prolonged, save the open files and turn off the computer. With the optional USB/RS232 communication port and the appropriate monitoring software, this shutdown can be automated.
  • Keep the batteries cool. Do not place the UPS in direct sunlight, near the heater or in closed cabinets; the operating temperature is 0–40 °C.
  • Allow time for charging after downtime. Batteries are charged to 90% capacity in 6–8 hours. In case of consecutive outages, the duration of the second outage is shorter.
  • If longer is required This series is not designed to connect an external battery. With an additional charging card for a long time, external battery can be connected single-phase online UPS models.

Service life and battery replacement

Batteries: this model uses a 2 × 12 V 7 Ah maintenance-free dry type (VRLA-AGM) battery. The design life of this class of batteries at 20 °C is usually 5 years in the manufacturer's data sheets. Changes in the UPS depending on the temperature and frequency of interruptions are often 3–5 years required. As the ambient temperature rises, the battery life is significantly shortened.

Have the batteries checked or replaced if:

  • If the duration of the interruption has been significantly shortened compared to the previous
  • If the UPS gives a battery warning or shows an error in the power-on test
  • If there is swelling, leakage or odor in the battery case
  • If the batteries are over 3 years old (annual measurement is recommended)

Detailed information: When should a UPS battery be replaced?

Two batteries in models with two batteries togethermust be replaced with a new one of the same capacity and type; the old and new battery are not mixed.

Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. The device is guaranteed for 2 years, and the spare part is provided for 10 years.

Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.

General Features

  • LED control panel
  • Microprocessor digital control
  • Automatic voltage adjustment (AVR)
  • Wide input voltage range (170~280 V)
  • Automatic fuse
  • Easy-to-understand alarm system
  • Output power factor 0.6
  • Cold start
  • Simulated sine wave output
  • Intelligent battery control system
  • Short circuit and overcurrent protection
  • Battery deep discharge protection
  • Automatic frequency detection
  • Shutdown in no-load operation in battery mode
  • Boot self-testing
  • Automatic battery charging in the switched off position
  • RS232 / USB communication port (optional)
  • LCD display (optional)
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Rear Panel

  1. Exodus
  2. Wire/modem/fax protection (optional)
  3. USB (optional)
  4. Introduction
  5. Insurance
  6. Fan (2000 VA)
Share
Technical Specifications
Series Myon
Power 1 kVA
Active power 600 W
Phase structure Single-phase (1/1)
Topology Line Interactive
Cabin type Tower
Output power factor 0,6
Waveform Simulated sine wave
Battery voltage 24 Vdc
Number of batteries 2 number
Battery type 2 × 12 V 7 Ah
Long-term (additional recharge card) Nope
Transfer period < 8–10 ms
Parallel processing None
Screen LED
Communications RS232 / USB (optional)
Dimensions (WxDxH) 136 × 328 × 186 mm
Net weight 9,4 kg
Warranty 2 years / 10 years of spare parts
Input voltage 220 / 230 / 240 VAC; range 162–295 VAC
Input frequency 50/60 Hz automatic detection
Output voltage regulation ±10% (battery operation)
Output frequency 50/60 Hz ± 1 Hz
Battery protection Overload, short circuit, deep discharge, overcharge protection
Battery management Yes
Display indicators Green LED for normal mains operation / yellow LED for battery operation / red LED for fault
Alarms Audible alerts for battery operation, low battery, and overload
Battery start (cold start) Yes
Short-circuit protection AC fuse + electronic protection on the mains; electronic protection on the battery
Voltage regulation 2-step boost and AVR
Operating temperature 0–40 °C
Noise (1 m) < 45 dB
Standards Safety IEC/EN 62040-1; EMC IEC/EN 62040-2
Outlets 3
Packaged dimensions (WxDxH) 185 × 374 × 269 mm
Gross weight 10 kg
Battery charging time 6–8 hours to 90% capacity
Warranty2 year
Weight9,4 kg
StatusZero
StockSold out

The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.

Delivery Process

  • It will be shipped within 1–3 business days.
  • The tracking number is shared by email and in My Account → My Orders.
  • When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
  • Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.

Returns and exchanges

  • You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
  • The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
  • Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
  • Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
  • Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
  • The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.

Full delivery and return conditions

Customer reviews

There are no reviews for this product yet.

If you've used this product, share your experience—be the first to leave a review.

Rate this product

  • Your rating and a few sentences will help guide other customers.
  • You decide whether your name, city, and photo will be displayed.
  • If you purchased it from us, the "Purchased" badge will appear in your review.
Log in and rate it

Log in to post a comment.

Write via WhatsApp