6 V 5 Ah high-current maintenance-free dry type (VRLA-AGM) battery for emergency lighting, alarms and 6 V devices. No water or acid additions required; 8 years design life in buffer use.

  • CE Conformity Mark CE
  • UL
  • ISO 9001
  • ISO 14001
  • OHSAS 18001
  • Description
  • Technical Specifications
  • Documents (1)
  • Delivery and Returns
  • Comments (0)

Ritar HR6-20WIt is a 6 V 5 Ah dry type battery produced with valve-regulated lead acid (VRLA) technology, with its electrolyte impregnated with glass fiber separators (AGM). It does not require the addition of water or acid, it does not require maintenance.

With its 70 × 47 × 105 mm dimensions, it is used in devices operating with 6 V such as emergency lighting, alarms and scales; 12 V is obtained by connecting two batteries in series. Its poles are 6.35 mm faston (F2) type.

Ritar HR (High Rate) is the series designed to deliver high power in a short time: thanks to the reinforced grid, thick plate and special active material, it has low internal resistance and self-discharge, according to the manufacturer, it delivers about 30% more power than the standard series; it is suitable for high-power standby applications such as data center, UPS and EPS.

Where is it used?

6 V 5 Ah batteries, which are activated when the power is cut off. Standby (buffer) use Designed for: the battery is kept fully charged at all times while the device is connected to the mains, feeding the device in case of an outage.

  • Emergency lighting and direction fixtures
  • Alarm and security systems
  • Electronic scales and measuring instruments
  • Backup supply of medical and laboratory devices
  • Toy vehicles and portable devices

The 8-year design life in the datasheet is for buffer use. In cyclic use, which discharges and fills up every day, the life depends on the number and depth of discharge.

How long does it last? (calculated, estimated)

The following times are manufacturer measurement It is not; From the discharge table in the data sheet of this battery Calculated Estimate values. Valid in a 25 °C environment with a new and fully charged battery.

Power drawn by the deviceEstimated time
15 W~1.3 hours
20 W~56 min
30 W~33 min
80 W~9 min

How was it calculated? The constant power table in the datasheet (25 °C, 1.75 V cut-off per cell) was used; the load was supplied directly from the battery (6 V DC) was accepted. Method detail: How to calculate battery time?

Manufacturer's discharge values (single battery, 25 °C, 1.75 V cut-off per cell):

DurationConstant currentThe power of the battery
5 min18.44 A103 W
10 min13.07 A73 W
15 min9.917 A56 W
30 min5,744 A33 W
1 hour3,278 A19 W

The actual time varies according to the age of the battery, the ambient temperature and the variability of the load; it is significantly shortened in aged batteries.

Choosing the right battery

  • Voltage: 6 V. If your device requires 12 V, two 6 V batteries are connected in series.
  • Size: 70 × 47 mm base, 105 mm height with poles (± 1.5 mm). Fits in the battery compartment or cabinet shelf, and the lid closes easily.
  • Pole Type: 6.35 mm faston (F2). The female faston end on your cable should also be 6.35 mm; 4.8 mm leads will not fit on this pole.
  • Capacity: All batteries in a group must be of the same capacity. The longer the capacity, the longer the time; the charging current of the UPS or charger must be sufficient, otherwise the full charging time will be longer. Equally higher capacity model: HR6-22W.
  • Type: UPSs charge according to the dry type (VRLA-AGM) battery; the flooded (well-maintained) automobile battery is not installed in the UPS.
  • Batteries in the array: It must be the same model and, if possible, from the same production date.

Charging, mounting and safety

  • Standby (buffer) charging: 6.85 – 6.95 V at 25 °C, temperature correction –3 mV/°C per cell; –9 mV/°C per battery. UPSs and alarm panels make this setting themselves.
  • Equalization Charge: 7.3 – 7.4 V at 25 °C, temperature correction –4 mV/°C per cell; –12 mV/°C per battery. If charging with a separate charger, use an AGM-set device that matches these values.
  • Charging current: the highest charging current recommended by the manufacturer is 1.5 A.
  • Assembly: switch off the device and disconnect it from the mains; do not connect the polarity backwards (red +, black –). Faston ends should fit all the way — loose contact will heat up.
  • Short Circuit: The short-circuit current of the battery is 278 A. Do not touch the two poles with the metal tool at the same time, remove the ring and watch when installing.
  • Environment: Use the batteries in a ventilated location away from the heat source and direct sun.

Life, storage and change

  • Design life: 8 years in buffer use. Real life; It depends on the ambient temperature, number and depth of discharge. Keeping the environment where the batteries are located at 20-25 °C preserves life.
  • Temperature: the recommended operating temperature is 25 ± 5 °C; the battery ages faster in a hot environment, and the capacity it can give decreases in the cold.
  • Storage: while the battery is unused, it discharges at most 3% per month at 25 °C; it should be kept for a maximum of 6 months and then refresh charged, more frequently in hot environment.
  • Time to change: If the duration of the UPS has shortened significantly, if it gives a battery warning or if the battery is swollen, it is time for a replacement. When should a UPS battery be replaced?
  • Waste battery: Used batteries are not disposed of in household waste; they are handed over to waste battery collection points.

Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.

Share
Technical Specifications
Nominal voltage 6 V
Nominal capacity 5 Oh
Battery technology VRLA – AGM (maintenance-free, dry type)
Design life 8 year
Pole (terminal) type 6.35 mm faston
Dimensions (L × W × H) 70 × 47 × 99 mm
Total height (with pole) 105 mm
Internal resistance approximately 22 mΩ
Short circuit current 278 A
Case material ABS (UL94-HB; UL94-V0 optional)
Capacity 5 Ah — reference capacity (C20) of 20 hours in the data sheet; the manufacturer classifies this model with a power rating of 15 minutes
Polar code (manufacturer) F2
Power rating (manufacturer) 20 W/cell — up to 1.67 V per cell at 15 minutes of discharge, 25 °C (60 W per battery)
Reference capacity (25 °C) C10 4.6 Ah · C20 5 Ah
Highest discharge current 50 A (5 sec)
Peak charging current 1.5 A
Standby (buffer) charging voltage, 25 °C 6.85 – 6.95 V (temperature correction –3 mV/°C per cell; –9 mV/°C per battery)
Equalization charging voltage, 25 °C 7.3 – 7.4 V (temperature correction –4 mV/°C per cell; –12 mV/°C per battery)
Operating temperature Discharge –20 ... · 60 °C Charge 0 ° · 50 °C · Storage –20 °C °C
Recommended operating temperature 25 ± 5 °C
Self-emptying Up to 3% per month at 25 °C
Storage Maximum 6 months at 25 °C, then refresh charge (more frequent in heat)
Dimension tolerance ± 1.5 mm
Warranty2 year
Weight0,72 kg
StatusZero
StockSold out

Batteries are delivered with their original pole protectors and without any connection to the poles. For withdrawal, the battery must not be used, charged/discharged and the terminals must not be connected; batteries that are installed and used will not be returned or will be deducted from the loss of value. Check the capacity and size suitable for your UPS before ordering; in case of wrong selection, the return shipping is your responsibility.

Delivery Process

  • It will be shipped within 1–3 business days.
  • The tracking number is shared by email and in My Account → My Orders.
  • When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
  • Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.

Returns and exchanges

  • You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
  • The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
  • Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
  • Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
  • Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
  • The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.

Full delivery and return conditions

Customer reviews

There are no reviews for this product yet.

If you've used this product, share your experience—be the first to leave a review.

Rate this product

  • Your rating and a few sentences will help guide other customers.
  • You decide whether your name, city, and photo will be displayed.
  • If you purchased it from us, the "Purchased" badge will appear in your review.
Log in and rate it

Log in to post a comment.

Write via WhatsApp