10 kVA / 10000 W 3 phase input / 1 phase output online double conversion UPS; 16 × 12 V 7–9 Ah built-in battery, LCD display, parallel operation with up to 3 devices. Myton series, 2 years warranty.

  • CE Conformity Mark CE
  • Description
  • Technical Specifications
  • Documents (1)
  • Delivery and Returns
  • Comments (0)

General Features

  • High frequency 3 level technology
  • DSP technology
  • Intelligent active input power factor correction (PFC)
  • Both 3 phase and 1 phase input operation
  • Wide input voltage range (110~300 V)
  • Output power factor 1
  • Cold start
  • Automatic frequency detection
  • ECO mode
  • Adjustable output voltage and operating mode from LCD (3/1 – 1/1)
  • 50/60 Hz frequency conversion mode
  • Charging current setting 1–4 A from the front panel
  • 16–20 batteries selectable
  • Advanced event memory recording
  • Boot self-testing
  • Advanced battery management (ABM)
  • Short circuit and overload protection
  • Automatic battery charging in the switched off position
  • Intelligent load-sensing fan control
  • Generator compatibility
  • Standard RS232/USB
  • Standard manual bypass
  • Standard EPO
  • SNMP (optional)
  • Add-on battery unit with additional magazine card (optional)
  • N+X paralleling (optional)
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Rear Panel

  1. EPO
  2. Fan
  3. RS232
  4. Bypass insurance
  5. Entrance insurance
  6. Cable fastening
  7. Communication slot
  8. USB port
  9. Ethernet port
  10. Extra battery connection socket
  11. Dry contact card
  12. WLAN socket

Where is it used?

The Myton 3110 10 kVA 3/1 online (double conversion) UPS supplies the load from its inverter at any time; when the power is cut off, the transition time to the battery is 0 ms and the output is full sine. It is supplied from the three-phase mains (or single-phase), providing a single-phase output. It is suitable for places that need to protect multiple devices together:

  • Small and medium-sized server rooms
  • Offices with multiple workstations
  • Clinical and laboratory equipment
  • Security, camera and building automation systems
  • Telecom and network rooms
  • Industrial control cabinets

Loads that should not be connected: devices such as laser printers, heaters, irons, water heaters, air conditioners with high inrush current or continuous high power overload the UPS and consume battery time in a short time; connect these devices to a normal outlet, not to the UPS.

Growth and redundancy: Power can be increased with N+X parallel operation (optional) or redundant installation.

Which devices run and how much? (calculated, estimated)

The following times are manufacturer measurement It is not; According to the battery arrangement of the device Calculated Estimate values. Valid for new and fully charged batteries in a 25 °C environment.

Connected loadTotal loadEstimated time
25% load2.5 kW~12 min
50% load5 kWLess than 5 min
75% load7.5 kWLess than 5 min
100% load10 kWLess than 5 min

How was it calculated? This model has a 16 × 12 V 7–9 Ah battery; the times are read from the constant power table (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheet for an AGM battery of class 7 Ah — with 9 Ah batteries, the duration is slightly longer. The inverter efficiency is considered to be 90% when operating from the battery (the manufacturer has not published the efficiency value from the battery for this model). Method detail: How to calculate battery time?

The actual time varies according to the age of the batteries, temperature and variability of the load; the time is significantly shortened in aged batteries. Since the UPS's own consumption is dominant in very small loads, the time cannot be calculated with this method.

How much load does it carry?

The strength of this model 10 kVA / 10 kW(output power factor 1). The sum of the connected devices must not exceed both the VA and watt limits.

Continuous load up to 8 kW (80% of the power). This allowance covers the short-term high current of the devices at power-up, extends the operating time from the battery and leaves room for growth.

  • Overload resistance: Continues at 100–105% load; 10 min at 105–125% load; 1 min at 125–150% load; 500 ms above 150%
  • 0ms switching from mains to battery, full sine output
  • Input power factor 0.95 ≥ at 3-phase input, 0.99 ≥ at single-phase input — works with generator
  • Short circuit, overload and battery deep discharge protection

If you don't know the total power of the devices you're connecting Power Calculation tool.

What can be done to extend the working time?

  • Connect only the necessary devices. Plug devices that do not need to operate in an outage into a normal outlet, not into a UPS.
  • Reduce the load. When the load is halved, the time is more than doubled (see table above).
  • Shut down systems with confidence. The communication port of the UPS (RS232/USB/SNMP) can be used with the appropriate monitoring software for the servers and computers to shut down properly during a long outage.
  • Keep the batteries cool. Do not place the UPS and batteries in direct sunlight, close to a heat source, or in stuffy places; the operating temperature is 0–40 °C.
  • Allow time for charging after downtime. Batteries are filled to 90% capacity in 3 hours. In case of consecutive outages, the duration of the second outage is shorter.
  • If longer is required an external battery unit can be added to this model with an additional magazine card (optional); the time is extended with the capacity of the added battery group. Let's calculate the appropriate group together: Contact Us.

Service life and battery replacement

Batteries: this model uses a 16 × 12 V 7–9 Ah maintenance-free dry type (VRLA-AGM) battery. The design life of this class of batteries at 20 °C is usually 5 years in the manufacturer's data sheets. Changes in the UPS depending on the temperature and frequency of interruptions are often 3–5 years required. As the ambient temperature rises, the battery life is significantly shortened.

Have the batteries checked or replaced if:

  • If the duration of the interruption has been significantly shortened compared to the previous
  • If the UPS gives a battery warning or shows an error in the battery test
  • If there is swelling, leakage or odor in the battery case
  • If the batteries are over 3 years old (annual measurement is recommended)

Detailed information: When should a UPS battery be replaced?

Batteries in a battery string togetheris replaced with a new one of the same capacity and type; the old and new battery are not mixed in the same sequence. Why?

Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. In online UPSs, fans and capacitors are parts that wear out over time; they are checked during periodic maintenance. The device is guaranteed for 2 years, and the spare part is provided for 10 years.

Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.

General Features

  • High frequency 3 level technology
  • DSP technology
  • Intelligent active input power factor correction (PFC)
  • Both 3 phase and 1 phase input operation
  • Wide input voltage range (110~300 V)
  • Output power factor 1
  • Cold start
  • Automatic frequency detection
  • ECO mode
  • Adjustable output voltage and operating mode from LCD (3/1 – 1/1)
  • 50/60 Hz frequency conversion mode
  • Charging current setting 1–4 A from the front panel
  • 16–20 batteries selectable
  • Advanced event memory recording
  • Boot self-testing
  • Advanced battery management (ABM)
  • Short circuit and overload protection
  • Automatic battery charging in the switched off position
  • Intelligent load-sensing fan control
  • Generator compatibility
  • Standard RS232/USB
  • Standard manual bypass
  • Standard EPO
  • SNMP (optional)
  • Add-on battery unit with additional magazine card (optional)
  • N+X paralleling (optional)
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Rear Panel

  1. EPO
  2. Fan
  3. RS232
  4. Bypass insurance
  5. Entrance insurance
  6. Cable fastening
  7. Communication slot
  8. USB port
  9. Ethernet port
  10. Extra battery connection socket
  11. Dry contact card
  12. WLAN socket
Share
Technical Specifications
Series Myton
Power 10 kVA
Active power 10000 W
Phase structure 3-phase input / 1-phase output (3/1)
Topology Online double-loop
Cabin type Tower
Output power factor 1
Waveform Pure sine wave
Battery voltage 192 Vdc
Number of batteries 16 number
Battery type 16 × 12 V, 7–9 Ah internal
Long-term (additional recharge card) Nope
Charging current 2 A (adjustable from 0 to 4 A)
Transfer period 0 ms (ECO → inverter 10 ms)
Parallel processing Up to 3 devices (optional)
Screen LCD
Communications RS232 (DB9), USB 2.0 HID, EPO, dry contact, Ethernet RJ45 (standard); network card / Modbus / AS400 / WLAN (optional); Winpower software
Dimensions (WxDxH) 220 × 492 × 589 mm
Net weight 85 kg
Warranty 2 years / 10 years of spare parts
Input 3/1-phase or 1/1-phase
Input voltage range 160–275 ±5 Vac at 100% load; 110–160 ±5 Vac at 50% load
Input frequency 50/60 Hz; 40–70 Hz (45–55 / 54–66 Hz when load is above 60% and in 1/1 operation)
Input power factor 3-phase input ≥ 0.95 / 1-phase input ≥ 0.99
Input THDi 3-phase ≤ 30% / 1-phase ≤ 5%
Output voltage 220 / 230 / 240 Vac
Voltage regulation ±1%
Output frequency 50/60 Hz
Crest factor 3:1
THDv ≤ 1% for linear loads; ≤ 5% for non-linear loads
Overload 100–105% continuous; 105–125%: 10 min; 125–150%: 1 min; >150%: 500 ms
Efficiency Online ≥ 95%; ECO ≥ 98%
Battery 192 / 240 Vdc, 16 or 20 batteries, adjustable via LCD; 90% in 3 hours
Display Dot matrix LCD, 10 languages
Dry contact 1 programmable input / 1 programmable output
Frequency converter mode Yes (1-phase input / 1-phase output, 60% power reduction)
Operating temperature / humidity / protection 0–50 °C (50% power loss at 40–50 °C), 0–95%, IP20
Noise (1 m) ≤ 55 dB
Operating altitude 0–3000 m (1% power loss per 100 m)
Standards CE / IEC / EN 62040; EMI C3; IEC/EN 61000-4-2/3/4/5
Accessories Maintenance bypass, EBM cable, USB cable, user manual; RS232 cable optional
Gross weight 90 kg
Warranty2 year
Weight85 kg
StatusZero
StockSold out

The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.

Delivery Process

  • It will be shipped within 1–3 business days.
  • The tracking number is shared by email and in My Account → My Orders.
  • When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
  • Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.

Returns and exchanges

  • You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
  • The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
  • Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
  • Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
  • Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
  • The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.

Full delivery and return conditions

Customer reviews

There are no reviews for this product yet.

If you've used this product, share your experience—be the first to leave a review.

Rate this product

  • Your rating and a few sentences will help guide other customers.
  • You decide whether your name, city, and photo will be displayed.
  • If you purchased it from us, the "Purchased" badge will appear in your review.
Log in and rate it

Log in to post a comment.

This product has been reviewed 55 times

Write via WhatsApp