3 kVA / 2700 W single-phase online double conversion UPS; 6 × 12 V 7–9 Ah built-in battery, LCD display, parallel operation with up to 3 devices. Myton series, 2 years warranty.

  • CE Conformity Mark CE
  • Description
  • Technical Specifications
  • Documents (1)
  • Delivery and Returns
  • Comments (0)

General Features

  • High frequency true double-conversion
  • DSP technology
  • Input power factor correction (PFC)
  • Wide input voltage range (110~300 V)
  • Show runtime from remaining battery
  • LED warning that changes color according to the operating mode
  • Output power factor 0.9
  • Cold start
  • Automatic frequency detection
  • Frequency converter mode
  • ECO mode
  • Selectable output voltage from LCD display
  • Boot self-testing
  • Advanced battery management (ABM)
  • Short circuit and overload protection
  • Automatic battery charging in the switched off position
  • Intelligent load-sensing fan control
  • Generator compatibility
  • Standard RS232/USB
  • Standard EPO
  • SNMP / AS400 / Modbus (optional)
  • Add-on battery unit with additional magazine card (optional)
  • Up to 3 parallel operation (optional)
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Rear Panel

  1. RS232
  2. EPO
  3. USB
  4. Introduction
  5. Exodus
  6. Communication card slot
  7. External battery
  8. Output terminal

Where is it used?

The Myton 3 kVA online (double conversion) UPS feeds the load from its inverter at any time; when the power is cut off, the transition time to the battery is 0 ms and the output is full sine. Suitable for devices sensitive to interruption and voltage disturbance:

  • Servers, networking and communication cabinets
  • Camera recording systems and security boards
  • Devices that require full sine voltage such as combi boilers
  • Laboratory and measuring devices
  • Automation and control panels (PLC)
  • Office computers and POS systems

Loads that should not be connected: devices such as laser printers, heaters, irons, water heaters, air conditioners with high inrush current or continuous high power overload the UPS and consume battery time in a short time; connect these devices to a normal outlet, not to the UPS.

Which devices run and how much? (calculated, estimated)

The following times are manufacturer measurement It is not; According to the battery arrangement of the device Calculated Estimate values. Valid for new and fully charged batteries in a 25 °C environment.

Connected loadTotal loadEstimated time
Server + network switch + modem455 W~30 min
3 workstations (computer + monitor) + network switch580 W~22 min
2 servers + network switch + NAS900 W~12 min
Half load (50%)1.4 kW~6 min
4 servers + 2 network switches + NAS1.7 kWLess than 5 min
Full load (100%)2.7 kWLess than 5 min

How was it calculated? This model is equipped with a 6 × 12 V 7–9 Ah battery; the times are read from the constant power table (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheet for an AGM battery of class 7 Ah — with 9 Ah batteries, the duration is slightly longer. The inverter efficiency is considered to be 85% when operating from the battery (the manufacturer has not published a battery efficiency value for this model). The device wattage values are available on our website Power Calculation tool; the value on the label of your own devices may be different. Detail of the method: How to calculate battery time?

The actual time varies according to the age of the batteries, temperature and variability of the load; the time is significantly shortened in aged batteries. Since the UPS's own consumption is dominant in very small loads, the time cannot be calculated with this method.

How much load does it carry?

The strength of this model 3,000 VA / 2,700 W(output power factor 0.9). The sum of the connected devices should not exceed both the VA and watt limits.

Continuous load up to 2.2 kW (80% of the power). This allowance covers the short-term high current of the devices at power-up, extends the operating time from the battery and leaves room for growth.

  • Overload resistance: Continues at 100–105% load; 60 s at 105–130% load; 10 s at 130–150% load; 300 ms above 150%
  • 0ms switching from mains to battery, full sine output
  • Input power factor ≥ 0.98 — works with the generator
  • Short circuit, overload and battery deep discharge protection

If you don't know the total power of the devices you're connecting Power Calculation tool.

What can be done to extend the working time?

  • Connect only the necessary devices. Plug devices that do not need to operate in an outage into a normal outlet, not into a UPS.
  • Reduce the load. When the load is halved, the time is more than doubled (see table above).
  • Shut down systems with confidence. The communication port of the UPS (RS232/USB/SNMP) can be used with the appropriate monitoring software for the servers and computers to shut down properly during a long outage.
  • Keep the batteries cool. Do not place the UPS and batteries in direct sunlight, close to a heat source, or in stuffy places; the operating temperature is 0–40 °C.
  • Allow time for charging after downtime. Batteries are filled to 90% capacity in 5 hours. In case of consecutive outages, the duration of the second outage is shorter.
  • If longer is required An external battery unit can be added to this model with an additional magazine card (optional). Powered by an external battery pack where hours are needed long-term online UPS models.

Service life and battery replacement

Batteries: this model uses a 6 × 12 V 7–9 Ah maintenance-free dry type (VRLA-AGM) battery. The design life of this class of batteries at 20 °C is usually 5 years in the manufacturer's data sheets. Changes in the UPS depending on the temperature and frequency of interruptions are often 3–5 years required. As the ambient temperature rises, the battery life is significantly shortened.

Have the batteries checked or replaced if:

  • If the duration of the interruption has been significantly shortened compared to the previous
  • If the UPS gives a battery warning or shows an error in the battery test
  • If there is swelling, leakage or odor in the battery case
  • If the batteries are over 3 years old (annual measurement is recommended)

Detailed information: When should a UPS battery be replaced?

Batteries in a battery string togetheris replaced with a new one of the same capacity and type; the old and new battery are not mixed in the same sequence. Why?

Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. In online UPSs, fans and capacitors are parts that wear out over time; they are checked during periodic maintenance. The device is guaranteed for 2 years, and the spare part is provided for 10 years.

Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.

General Features

  • High frequency true double-conversion
  • DSP technology
  • Input power factor correction (PFC)
  • Wide input voltage range (110~300 V)
  • Show runtime from remaining battery
  • LED warning that changes color according to the operating mode
  • Output power factor 0.9
  • Cold start
  • Automatic frequency detection
  • Frequency converter mode
  • ECO mode
  • Selectable output voltage from LCD display
  • Boot self-testing
  • Advanced battery management (ABM)
  • Short circuit and overload protection
  • Automatic battery charging in the switched off position
  • Intelligent load-sensing fan control
  • Generator compatibility
  • Standard RS232/USB
  • Standard EPO
  • SNMP / AS400 / Modbus (optional)
  • Add-on battery unit with additional magazine card (optional)
  • Up to 3 parallel operation (optional)
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Rear Panel

  1. RS232
  2. EPO
  3. USB
  4. Introduction
  5. Exodus
  6. Communication card slot
  7. External battery
  8. Output terminal
Share
Technical Specifications
Series Myton
Power 3 kVA
Active power 2700 W
Phase structure Single-phase (1/1)
Topology Online double-loop
Cabin type Tower
Output power factor 0,9
Waveform Pure sine wave
Battery voltage 72 Vdc
Number of batteries 6 number
Battery type 6 × 12 V 7–9 Ah internal
Long-term (additional recharge card) Nope
Charging current 1 A (standard); 6 A (long-term L); 90% in 5 hours
Transfer period Battery to inverter: 0 ms; inverter to bypass: < 4 ms; ECO to battery: < 10 ms
Parallel processing Up to 3 devices (optional)
Screen LCD
Communications RS232, USB, and EPO are standard; SNMP, Modbus, and AS400 cards are optional
Dimensions (WxDxH) 190 × 391 × 297 mm
Net weight 25 kg
Warranty 2 years / 10 years of spare parts
Input voltage 208 / 220 / 230 / 240 VAC; 176–300 VAC at 100% load, 110–300 VAC at 50% load
Input frequency 45–55 / 54–66 Hz
Input power factor ≥ 0.98
Output voltage 200 / 208 / 220 / 230 / 240 Vac selectable (10% power reduction at 200/208)
Voltage regulation ±1%
Output frequency 50/60 Hz ±0.05 Hz
Crest factor 3:1
Harmonic distortion ≤ 2% for linear loads; ≤ 5% for non-linear loads
Overload 100–105% continuous; 105–130%: 60 sec; 130–150%: 10 sec; >150%: 300 ms
Efficiency (from utility grid) ≥ 91%
Alarms Mains failure, low battery, overload, general fault — audible / LED
Display Segment LCD
Noise (1 m) ≤ 45–48 dB
Operating temperature / humidity / protection 0–40 °C, 20–90% (non-condensing), IP20
Standards CE, IEC/EN 62040-1/2
Accessories User manual, RS232 cable, power cord
Outlets 4 outlets
Gross weight 27 kg
Warranty2 year
Weight25 kg
StatusZero
StockSold out

The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.

Delivery Process

  • It will be shipped within 1–3 business days.
  • The tracking number is shared by email and in My Account → My Orders.
  • When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
  • Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.

Returns and exchanges

  • You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
  • The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
  • Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
  • Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
  • Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
  • The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.

Full delivery and return conditions

Customer reviews

There are no reviews for this product yet.

If you've used this product, share your experience—be the first to leave a review.

Rate this product

  • Your rating and a few sentences will help guide other customers.
  • You decide whether your name, city, and photo will be displayed.
  • If you purchased it from us, the "Purchased" badge will appear in your review.
Log in and rate it

Log in to post a comment.

Write via WhatsApp