TCMB foreign exchange selling rate · 24.11.2026: USD 50,63 ₺ EUR 55,32 ₺

Bempower Myon 3310 10 kVA Three-Phase Online UPS

Sold out
Bempower

Bempower Myon 3310 10 kVA Three-Phase Online UPS

Model code
3310
Series
Myon
Status
Zero
Stock
Sold out
Warranty
2 year
There are no reviews yet — be the first to write a review
Sold out supplying, you can request a quote

10 kVA / 10,000 W three-phase online double-conversion UPS; 12 V 7–9 Ah; 32–40 adjustable batteries; touchscreen LCD display; parallel operation with up to 6 units. Myon series, 2-year warranty.

  • CE Conformity Mark CE
  • Description
  • Technical Specifications
  • Documents (1)
  • Delivery and Returns
  • Comments (0)

General Features

  • High frequency online double conversion
  • Dual-core DSP control, three-level technology
  • Active power factor correction (APFC), input power factor up to 0.99
  • System efficiency 95%
  • Output power factor 1.0
  • Dual entry (split bypass) supporting independent bypass
  • High reliability with digital parallel technology
  • Wide input voltage range
  • 50/60 Hz auto-sensing and frequency conversion mode
  • Up to 98% efficiency in ECO mode
  • Intelligent fan speed that varies according to load
  • Flexible battery configuration: 32~40 batteries
  • Digitally controlled charger (max. 20 A, 20% of output power)
  • Cold start
  • Zero switching time in grid instability
  • Compact design, 5-inch color touchscreen LCD
  • Parameter configuration and online upgrade software
  • Multi-platform communication: RS232, USB, RS485, dry contact, SNMP, Wi-Fi, GPRS
  • Intelligent battery management (automatic equalization, variable charging control)
  • Self-diagnosis and event log
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty

Where is it used?

The Myon 3310 10 kVA three-phase online (double conversion) UPS supplies the load from its inverter at any time; when the power is cut off, the transition time to the battery is 0 ms and the output is full sine. Suitable for critical loads on a building or plant scale:

  • Data centers and server rooms
  • Hospital, clinic and laboratory infrastructures
  • Production line automation and control systems in factories
  • Critical loads of buildings such as banks, hotels, shopping malls
  • Telecom and broadcast centers
  • Security, fire and building management systems

Growth and redundancy: Up to 6 devices can work in parallel (optional); new device can be added as the load increases, or when one device fails, the other carries the load (N+1). Separate bypass input (split bypass) is supported.

Loads requiring a project: For loads with high starting current such as motors, pumps, compressors and large battery groups, UPS power and battery arrangement should be calculated at the project stage; we do the discovery and calculation together.

Which devices run and how much? (calculated, estimated)

The following times are manufacturer measurement It is not; According to the battery arrangement of the device Calculated Estimate values. Valid for new and fully charged batteries in a 25 °C environment.

Connected loadTotal loadEstimated time
25% load2.5 kW~17 min
50% load5 kW~6 min
75% load7.5 kWLess than 5 min
100% load10 kWLess than 5 min

How was it calculated? This model has a 20 × 12 V 7–9 Ah battery; the times are read from the constant power table (25 °C, 1.75 V cut-off per cell) in the manufacturer's data sheet for an AGM battery of class 7 Ah — with 9 Ah batteries, the duration is slightly longer. The inverter efficiency is considered to be 90% when operating from the battery (the manufacturer has not published the efficiency value from the battery for this model). Method detail: How to calculate battery time?

The actual time varies according to the age of the batteries, temperature and variability of the load; the time is significantly shortened in aged batteries. Since the UPS's own consumption is dominant in very small loads, the time cannot be calculated with this method.

How much load does it carry?

The strength of this model 10 kVA / 10 kW(output power factor 1). In three-phase output, the loads should be distributed to the phases as evenly as possible.

Continuous load up to 8 kW (80% of the power); this allowance both covers the start-up currents and leaves a growth allowance.

  • Inverter overload resistance: 60 min at 110% load; 10 min at 110–125% load; 1 min at 125–150% load; 200 ms above 150%
  • Bypass overload: continuous at 125% load; 10 min at 125–130% load; 1 min at 130–150% load; 1 sec at 150–400% load
  • Input power factor up to 0.99 (active PFC) — generator compatible
  • 0ms switching from mains to battery, full sine output

Let's determine the appropriate power and battery layout for your facility: UPS installation and assembly.

What can be done to extend the working time?

  • Connect only the necessary devices. Plug devices that do not need to operate in an outage into a normal outlet, not into a UPS.
  • Reduce the load. When the load is halved, the time is more than doubled (see table above).
  • If longer is required Let's evaluate the addition of an external battery group or our battery-free models (3340 / 3360) that work with an external battery group. The charging current of this model is up to 10 A.
  • Keep the battery room cool and ventilated. The capacity and lifespan of batteries are directly affected by temperature.
  • Use with generator. During long outages, the UPS acts as a bridge until the generator kicks in; batteries can only be selected enough to cover this break.
  • Perform battery tests regularly. With discharge and load tests The actual duration of the battery pack is measured.

Service life and battery replacement

Batteries: this model uses a 20 × 12 V 7–9 Ah maintenance-free dry type (VRLA-AGM) battery. The design life of this class of batteries at 20 °C is usually 5 years in the manufacturer's data sheets. Changes in the UPS depending on the temperature and frequency of interruptions are often 3–5 years required. As the ambient temperature rises, the battery life is significantly shortened.

Have the batteries checked or replaced if:

  • If the duration of the interruption has been significantly shortened compared to the previous
  • If the UPS gives a battery warning or shows an error in the battery test
  • If there is swelling, leakage or odor in the battery case
  • If the batteries are over 3 years old (annual measurement is recommended)

Detailed information: When should a UPS battery be replaced?

Batteries in a battery string togetheris replaced with a new one of the same capacity and type; the old and new battery are not mixed in the same sequence. Why?

Device: The UPS itself is used in a suitable environment (0–40 °C, dust-free, ventilated) for many more years than batteries. In three-phase online UPSs, fans and capacitors are parts that wear out over time; they are checked during periodic maintenance. The device is guaranteed for 2 years, and the spare part is provided for 10 years.

Battery replacement and Periodic Maintenance With our services, we measure your batteries and replace them on time.

General Features

  • High frequency online double conversion
  • Dual-core DSP control, three-level technology
  • Active power factor correction (APFC), input power factor up to 0.99
  • System efficiency 95%
  • Output power factor 1.0
  • Dual entry (split bypass) supporting independent bypass
  • High reliability with digital parallel technology
  • Wide input voltage range
  • 50/60 Hz auto-sensing and frequency conversion mode
  • Up to 98% efficiency in ECO mode
  • Intelligent fan speed that varies according to load
  • Flexible battery configuration: 32~40 batteries
  • Digitally controlled charger (max. 20 A, 20% of output power)
  • Cold start
  • Zero switching time in grid instability
  • Compact design, 5-inch color touchscreen LCD
  • Parameter configuration and online upgrade software
  • Multi-platform communication: RS232, USB, RS485, dry contact, SNMP, Wi-Fi, GPRS
  • Intelligent battery management (automatic equalization, variable charging control)
  • Self-diagnosis and event log
  • EMC – LVD CE
  • 2 years warranty / 10 years spare parts warranty
Share
Technical Specifications
Series Myon
Power 10 kVA
Active power 10000 W
Phase structure Three-phase (3/3)
Topology Online double-loop
Cabin type Tower
Output power factor 1
Waveform Pure sine wave
Battery voltage 240 Vdc
Number of batteries 20 number
Battery type 12 V, 7–9 Ah; 32–40 batteries (adjustable)
Long-term (additional recharge card) Nope
Charging current Max. 10 A
Efficiency (from the grid) 95 %
Transfer period 0 ms
Parallel processing Up to 6 devices (optional)
Screen Touchscreen LCD
Communications RS232, RS485, USB, EPO, dry contact, and parallel port are standard; SNMP, Wi-Fi, GPRS card, and SMS alarm are optional
Dimensions (WxDxH) 250 × 720 × 560 mm
Net weight 82 kg
Warranty 2 years / 10 years of spare parts
Input voltage 380 / 400 / 415 VAC (F-F), 228–478 VAC (3Φ+N+PE)
Introduction to THDi ≤ 1% for linear loads; ≤ 3% for nonlinear loads
Input frequency 50–60 Hz automatic detection; range 40–70 Hz ±0.5%
Bypass voltage range Factory setting -20% to +15%; lower/upper limits selectable via the LCD
Bypass frequency range ±1 / ±3 / ±5 Hz selectable
Bypass overload 125% continuous; 125%–130%: 10 min; 130%–150%: 1 min; 150%–400%: 1 sec; >400%: 200 ms
Output voltage 380 / 400 / 415 Vac, selectable via the LCD panel
Voltage regulation ±1% (with linear load)
Output frequency Synchronized with the grid; 50/60 Hz ±0.1 Hz from the battery
Crest factor 3:1
THDv ≤ 1% with linear load; ≤ 3% with non-linear load
Inverter overload 110%: 60 min; 110%–125%: 10 min; 125%–150%: 1 min; >150%: 200 ms
Charge voltage accuracy ≤ 1%
Alarms Battery operation, low battery, fan fault
Operating temperature / humidity 0–40 °C, 0–95% (non-condensing)
Noise (1 m) ≤ 58 dB
Storage temperature -40–70 °C
Operating altitude ≤ 1000 m; 1% power loss per 100 m at 1000–2000 m
Battery configuration (10+10) 20 × 12 V 7–9 Ah internal
Packaged dimensions (WxDxH) 350 × 800 × 722 mm
Packaged weight 93 kg
Warranty2 year
Weight82 kg
StatusZero
StockSold out

The device is sent insured; check the parcel for external damage without opening it in the presence of the cargo officer, and make a report of the damage. For withdrawal, the packaging of the device must be unopened and not commissioned, the serial number and labels must be intact, and the accessories must be complete. The commissioned or installed device is excluded from the return condition. Installation and commissioning are separate and paid services; it is optional at the payment step. Return shipping cost belongs to the buyer; except for the defective product.

Delivery Process

  • It will be shipped within 1–3 business days.
  • The tracking number is shared by email and in My Account → My Orders.
  • When picking, check the package with the cargo officer; if there is damage, make a report and do not receive it.
  • Heavy and multi-volume shipments are delivered by warehouse or vehicle; the time and fee are shown according to your address in the payment step.

Returns and exchanges

  • You can exercise your right of withdrawal within 14 days of delivery (individual purchases).
  • The product to be returned must be unused, in its original packaging, complete with the invoice and accessories.
  • Loss of value is deducted from products that have been installed and used, terminals connected or commissioned; if the use has made it impossible to return, the return will not be accepted.
  • Return shipping cost belongs to the buyer; For defective, damaged or incorrectly sent products, the price belongs to us.
  • Refunds will be made to your payment method no later than 14 days after the product has been received and inspected.
  • The legal right of withdrawal does not apply to corporate (commercial purposes) purchases; requests are evaluated separately.

Full delivery and return conditions

Customer reviews

There are no reviews for this product yet.

If you've used this product, share your experience—be the first to leave a review.

Rate this product

  • Your rating and a few sentences will help guide other customers.
  • You decide whether your name, city, and photo will be displayed.
  • If you purchased it from us, the "Purchased" badge will appear in your review.
Log in and rate it

Log in to post a comment.

This product has been reviewed 51 times

Write via WhatsApp